Long-term results of the ABG-1 hydroxyapatite coated total hip arthroplasty: Analysis of 111 cases with a minimum follow-up of 10 years - 09/12/09

Doi : 10.1016/j.otsr.2009.10.001 
R. Bidar , P. Kouyoumdjian, E. Munini, G. Asencio
Department of Orthopaedics and Traumatology, Carémeau Teaching Hospital Center, place du Pr-Robert-Debré, 30029 Nîmes cedex 9, France 

Corresponding author. Tel.: +33 6 64295802.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Summary

Introduction

Medium-term studies of ABG-1™ cementless total hip arthroplasty have shown favorable functional results with excellent femoral component fixation but an abnormally high rate of periacetabular component osteolysis, which may require early revision.

Hypothesis

The periacetabular osteolysis rate increases with time with the ABG-1™ implant, leading to a high revision rate.

Objective

The objective of this study was to test this hypothesis with a minimum follow-up of 10 years and evaluate the progression of periacetabular osteolysis and its consequences on implant fixation.

Material and methods

A continuous series of 111 ABG-1™ cementless prostheses implanted by a single operator with a theoretical minimum follow-up of 10 years. Seventy-five implants were analyzed with a mean follow-up of 13 years. All the prostheses had been implanted via a posterolateral approach and consisted of a 28mm cup matching a head in zirconia and an antidislocation rim design high-density polyethylene insert.

Results

Twelve cups were revised because of progressive retroacetabular osteolysis. The revisions were performed systematically although there was no pain or gross cup loosening. The revisions included resection of the granuloma, cavity filling with morselized bone grafts, and implantation of new uncemented ABG-2™ cups in eight cases or cemented cups associated with a support ring in the four other cases. Thirty-two (48.5%) of the cups still in place at the end of the follow-up evaluation presented moderate and asymptomatic radiographic osteolysis, inciting close subsequent observation. No predictive factor of osteolysis onset was identified (age, body mass index, polyethylene wear, or cup orientation). None of the femoral stems was changed because of osteolysis: the only two femoral revisions resulted from periprosthetic fracture and one case of bipolar loosening. The femoral osteolysis images were small and all limited to zones 7a (18.8% of cases), 1a, and 1b (65.2% of cases). The overall survival rate of the series at 13 years of follow-up was 80.5%; the cup survival rate was 83.2%; the femoral implant, 94.3%; and failure of the femoral stem secondary to aseptic loosening was only 1.3%.

Discussion, conclusion

This long-term study confirms the high frequency of retroacetabular osteolysis of ABG-1™ prostheses surpassing the osteolysis rate of other uncemented cups with a polyethylene insert. The absence of predictive criteria of osteolysis occurrence and the lack of symptoms warrants periodic follow-up of patients with ABG-1™ cups and, if necessary, early repair of bone stock loss with grafts combined with acetabular cup revision. This procedure remains simple as long as performed before the onset of massive bone destruction, confirming the proposed revisions in this series were judicious. This study also confirms the excellent long-term fixation of the ABG-1™ femoral stems derived from the osteointegration and proximal seal around the hydroxyapatite coating.

Level of evidence

Level IV: retrospective therapeutic study.

El texto completo de este artículo está disponible en PDF.

Keywords : Uncemented total hip arthroplasty, Hydroxyapatite coating, Osteolysis


Esquema


© 2009  Publicado por Elsevier Masson SAS.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 95 - N° 8

P. 579-587 - décembre 2009 Regresar al número
Artículo precedente Artículo precedente
  • Anterior dislocation of a total hip replacement. Radiographic and CT-scan assessment. Behavior following conservative management
  • M. Di Schino, F. Baudart, S. Zilber, A. Poignard, J. Allain
| Artículo siguiente Artículo siguiente
  • Severe slipped capital femoral epiphysis: The Dunn’s operation
  • M. Lawane, M. Belouadah, G. Lefort

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.