Summary

Introduction

Trochanteric fractures are commonly stabilized either by intramedullary nailing or plate and screw fixation after reduction on the orthopaedic surgical table under radiological guidance.

Hypothesis

Closed trochanteric fracture anatomic reduction is difficult in the transversal plane.

Objectives

The objective of this prospective study was to assess the rotational malalignment induced after reduction and osteosynthesis of trochanteric fractures.

Patients and methods

Prospective study including 40 patients (mean age, 78years; range, 51–90years) operated for a trochanteric fracture between January 2007 and September2008. Fourteen fractures were treated using DHS™ (Synthes™) plate and screw fixation and 26 with intramedullary nailing (trochanteric nail™, Stryker™). All these patients underwent postoperative CT of the pelvis during their hospitalization with measurement of anteversion of the operated and healthy femoral necks at the posterior condyles. The evaluation criterion was whether or not there was malalignment greater than 15° on the operated side compared to the healthy side.

Results

The mean anteversion was 14.2° for the healthy side and 23° for the operated side. The mean rotational malalignment was 15.3°. Forty percent of the rotational malalignments were greater than 15°, with a majority of cases showing excess internal rotation (35%) of the distal fragment.

Conclusion and discussion

The rate of internal rotational malalignment of the distal fragment greater than 15° was high (40% of this series). This should encourage surgeons to reduce the excess internal rotation that tends to be attributed to the distal fragment during preoperative reduction of these fractures.

Level of evidence

Level III. Prospective diagnostic study with no control group.

El texto completo de este artículo está disponible en PDF.

Keywords : Rotational malalignment, Trochanteric fractures, Torsional malunion


Esquema


© 2010  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 96 - N° 8

P. 844-848 - décembre 2010 Regresar al número
Artículo precedente Artículo precedente
  • Arthroplasty following a septic arthritis history: A 53 cases series
  • T. Bauer, S. Lacoste, L. Lhotellier, P. Mamoudy, A. Lortat-Jacob, P. Hardy
| Artículo siguiente Artículo siguiente
  • Total knee arthroplasty for osteoarthritis secondary to extra-articular malunions
  • G. Deschamps, F. Khiami, Y. Catonné, C. Chol, C. Bussière, P. Massin, The French Hip and Knee Society (S.F.H.G.) 1

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.