Suscribirse

Changes in reference vessel diameter in ST-segment elevation myocardial infarction after primary percutaneous coronary intervention: Implications for appropriate stent sizing - 06/08/11

Doi : 10.1016/j.ahj.2011.04.016 
Ecaterina Cristea, MD a, Gregg W. Stone, MD, FACC a, Roxana Mehran, MD, FACC a, b, Ajay J. Kirtane, MD, FACC a, Sorin J. Brener, MD, FACC c,
a Columbia University Medical Center and the Cardiovascular Research Foundation, New York, NY 
b Mount Sinai Medical Center and the Cardiovascular Research Foundation, New York, NY 
c New York Methodist Hospital and the Cardiovascular Research Foundation, Brooklyn and New York, NY 

Reprint requests: Sorin J. Brener MD, FACC, Cardiac Catheterization Laboratory, NY Methodist Hospital, 506 6th street, KP-2, Brooklyn, NY 11215.

Resumen

Background

Stents may be undersized during primary percutaneous coronary intervention (PCI) in ST-segment elevation myocardial infarction (STEMI), leading to higher rates of stent thrombosis. We sought to compare the reference vessel diameter (RVD) of the infarct-related artery before, immediately after, and at late follow-up after PCI for STEMI. We further investigated whether vessels treated with paclitaxel-eluting (PES) or bare-metal stents (BMS) behave differently with respect to RVD at follow-up.

Methods

From the HORIZONS-AMI trial, we identified 2,974 patients (3,589 lesions) with complete quantitative angiographic data for stent implantation (2,233 treated with PES and 741 treated with BMS).

Results

Considering all lesions, the median RVD was 2.87 mm (25th-75th percentile 2.54-3.22 mm) at baseline, 2.92 mm (2.58-3.28 mm) immediately post-PCI, and 2.88 mm (2.55-3.22 mm) after 13 months (1,197 patients; P = .001 pre vs post, P = .06 post vs follow-up, and P = .21 pre vs follow-up). There were no significant differences between the RVD for PES versus BMS at any period. The maximal stent or balloon size was 3.00 mm (3.00-3.50 mm) for both groups. There were no differences in RVD at baseline or post-PCI between patients with and without stent thrombosis.

Conclusions

Reference vessel diameter does not change substantially from baseline to follow-up, irrespective of stent type. Stent diameter was appropriate for vessel size. The RVD of patients with and without stent thrombosis was similar at baseline and post-PCI. Thus, the high rates of stent thrombosis after primary PCI for STEMI cannot be attributed to stent undersizing.

El texto completo de este artículo está disponible en PDF.

Esquema


© 2011  Mosby, Inc. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 162 - N° 1

P. 173-177 - juillet 2011 Regresar al número
Artículo precedente Artículo precedente
  • Polymorphisms associated with in vitro aspirin resistance are not associated with clinical outcomes in patients with coronary artery disease who report regular aspirin use
  • Deepak Voora, John Horton, Svati H. Shah, Linda K. Shaw, L. Kristin Newby
| Artículo siguiente Artículo siguiente
  • Association of initial Thrombolysis in Myocardial Infarction flow grade with mortality among patients with ST-segment elevation myocardial infarction undergoing primary percutaneous coronary intervention: A National Registry of Myocardial Infarction-5 (NRMI-5) analysis
  • Jinhui Wu, Yuri B. Pride, Paul D. Frederick, C. Michael Gibson

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.