Suscribirse

D-dimer Testing in Patients with Suspected Pulmonary Embolism and Impaired Renal Function - 12/08/11

Doi : 10.1016/j.amjmed.2009.03.032 
Reza Karami-Djurabi, MD, Frederikus A. Klok, MD, Judith Kooiman, Sophie I. Velthuis, Mathilde Nijkeuter, MD, PhD, Menno V. Huisman, MD, PhD
Section of Vascular Medicine, Department of General Internal Medicine – Endocrinology, Leiden University Medical Center, Leiden, the Netherlands 

Requests for reprints should be addressed to Menno V. Huisman, MD, PhD, LUMC (C4-70), Albinusdreef 2, Postbus 9600, 2300 RC Leiden, The Netherlands

Abstract

Background

Determination of pretest probability and D-dimer tests are the first diagnostic steps in patients with suspected pulmonary embolism, which can be ruled out when clinical probability is unlikely and D-dimer level is normal. We evaluated the utility of D-dimer testing in patients with impaired renal function.

Methods

D-dimer tests were performed in consecutive patients with suspected pulmonary embolism and an unlikely clinical probability. Creatinine levels were assessed as clinical routine. Glomerular filtration rate was calculated using the Modification of Diet in Renal Disease formula. Correlation between D-dimer level and renal function and proportions of patients with normal D-dimer in different categories of estimated glomerular filtration rate (eGFR) were assessed. Different categories of decreasing eGFR were defined as: normal renal function (eGFR >89 mL/min), mild decrease in eGFR (eGFR 60-89 mL/min), and moderate decrease in eGFR (eGFR 30-59 mL/min).

Results

Creatinine levels were assessed in 351 of 385 patients (91%). D-dimer levels significantly increased in 3 categories of decreasing eGFR (P = .027 and P = .021 for moderate renal impairment compared with mild renal impairment and normal renal function, respectively). Normal D-dimer levels were found in 58% of patients with eGFR >89 mL/min, in 54% with eGFR 60-89 mL/min, and in 28% with eGFR 30-59 mL/min.

Conclusions

The specificity of D-dimer testing in patients with suspected pulmonary embolism and decreased GFR is significantly decreased. Nonetheless, performing D-dimer tests is still useful because computed tomography scanning can be withheld in a significant proportion of these patients.

El texto completo de este artículo está disponible en PDF.

Keywords : Creatinine, D-dimer, Glomerular filtration rate, Pulmonary embolism, Renal function


Esquema


 Funding: This study was supported in part by unrestricted grants from our hospital.
 Conflict of Interest: None.
 Authorship: All authors had access to the data and a role in drafting and writing the manuscript.


© 2009  Elsevier Inc. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 122 - N° 11

P. 1050-1053 - novembre 2009 Regresar al número
Artículo precedente Artículo precedente
  • A1c Control in a Primary Care Setting: Self-titrating an Insulin Analog Pre-mix (INITIATEplus Trial)
  • David S. Oyer, Mark D. Shepherd, Franklin C. Coulter, Anuj Bhargava, Jason Brett, Pei-Ling Chu, Bruce S. Trippe, The INITIATEplus Study Group ⁎
| Artículo siguiente Artículo siguiente
  • Reducing Blood Sample Hemolysis at a Tertiary Hospital Emergency Department
  • Marcus Eng Hock Ong, Yiong Huak Chan, Chin Siah Lim

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.