Suscribirse

Failure to Validate the San Francisco Syncope Rule in an Independent Emergency Department Population - 21/08/11

Doi : 10.1016/j.annemergmed.2007.12.007 
Adrienne Birnbaum, MD, MS , David Esses, MD, Polly Bijur, PhD, Andrew Wollowitz, MD, E. John Gallagher, MD
Department of Emergency, Albert Einstein College of Medicine, Bronx, NY. 

Address for correspondence: Adrienne Birnbaum, MD, MS, Emergency Medicine, 1B21 Building #6, Jacobi Medical Center, Bronx, NY 10461; 718-918-5815, fax 718-918-7459

Resumen

Study objective

We conduct a prospective independent validation of the San Francisco Syncope Rule to identify emergency department (ED) syncope patients with short-term serious outcomes.

Methods

This was a prospective observational cohort study of adult patients presenting to a university hospital ED with acute syncope or near syncope. Patients meeting inclusion criteria as defined in the San Francisco Syncope Rule derivation were evaluated for 5 previously derived predictor variables: abnormal ECG result, shortness of breath, hematocrit level less than 30%, triage systolic blood pressure less than 90 mm Hg, and history of congestive heart failure. Hospital admission occurred at the discretion of the emergency physician, independent of the decision rule. Follow-up occurred through contact with the inpatient attending physician for admitted patients and by telephone contact with patients not hospitalized or those hospitalized and discharged before day 7. Predetermined outcome measures as defined by the San Francisco Syncope Rule were death, myocardial infarction, arrhythmia, pulmonary embolism, stroke, subarachnoid hemorrhage, significant hemorrhage, or any condition causing or likely to cause a return ED visit and hospitalization for a related event.

Results

Complete predictor and follow-up data were available for 713 of 743 (96%) enrolled patients. Sixty-one of 713 (9%) patients met predetermined criteria for serious outcome. Sixteen of 61 (26%; 95% confidence interval [CI] 16% to 39%) patients with a serious outcome were not identified as high risk by the rule. Rule performance to predict serious outcomes was sensitivity 74% (95% CI 61% to 84%), specificity 57% (95% CI 53% to 61%); negative likelihood ratio 0.5 (95% CI 0.3 to 0.7) and positive likelihood ratio 1.7 (95% CI 1.4 to 2.0).

Conclusion

In this independent validation study, sensitivity and negative likelihood ratio of the San Francisco Syncope Rule were substantially lower than reported in the original studies and suggest that the rule has limited generalizability.

El texto completo de este artículo está disponible en PDF.

Esquema


 Supervising editor: Robert Silbergleit, MD
 Funding and support: By Annals policy, all authors are required to disclose any and all commercial, financial, and other relationships in any way related to the subject of this article, that might create any potential conflict of interest. The authors have stated that no such relationships exist. See the Manuscript Submission Agreement in this issue for examples of specific conflicts covered by this statement.
 Author contributions: AB, DE, PB, and EJG conceived the study and designed the trial. DE and AW supervised the conduct of the trial and data collection. AB, DE, and AW managed the data, including quality control. PB provided statistical advice on study design and data analysis. AB analyzed the data. AB drafted the article, and all authors contributed substantially to its revision. AB takes responsibility for the paper as a whole.
 Publication dates: Available online February 20, 2008.
 Reprints not available from the authors.


© 2008  American College of Emergency Physicians. Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 52 - N° 2

P. 151-159 - août 2008 Regresar al número
Artículo precedente Artículo precedente
  • Balloon Compression as Treatment for Refractory Vaginal Hemorrhage
  • Nathaniel Ryan Schlicher
| Artículo siguiente Artículo siguiente
  • Empirical Characteristics of Litigation Involving Tissue Plasminogen Activator and Ischemic Stroke
  • Bryan A. Liang, Justin A. Zivin

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.