Suscribirse

Acute primary angle-closure: long-term intraocular pressure outcome in Asian eyes - 03/09/11

Doi : 10.1016/S0002-9394(00)00621-8 
Tin Aung a, ⁎  : FRCS, FRCOphth, Leonard P Ang a, b : FRCS, Siew-Pang Chan, MSc b, Paul T.K Chew a, c, 1 : FRCS, FRCOphth
a Singapore National Eye Centre (Drs Ang, Aung, and Chew) Singapore 
b Tan Tock Seng Hospital (Drs Ang and Chan), Singapore 
c National University of Singapore (Dr Chew), Singapore 

*Correspondence to Tin Aung, FRCS, FRCOphth, Flat 15, Boddington House, 40, Trinity Church Rd, Barnes, London SW13 8 EB, United Kingdom; fax: (44) 208-7486272

Abstract

PURPOSE: To report the long-term outcome of intraocular pressure after laser peripheral iridotomy in Asian eyes with acute primary angle-closure.

METHODS: Retrospective study of 111 eyes of 96 consecutive patients with acute primary angle-closure, presenting at the National University Hospital, Singapore, from 1990 to 1994. The presenting features of the affected eye and the treatment instituted were recorded. The subsequent long-term intraocular pressure outcome was analyzed. An increase in intraocular pressure on follow-up was defined as increase in intraocular pressure greater than 21 mm Hg and requiring treatment by medication or surgery.

RESULTS: The mean follow-up period was 50.3 months (range, 9 to 107 months). The mean presenting intraocular pressure was 52.8 mm Hg (range, 28 to 80 mm Hg). One hundred ten eyes were treated with laser peripheral iridotomy, with resolution of the acute episode and intraocular pressure less than 21 mm Hg in all eyes after laser peripheral iridotomy. Of these, only 46 eyes (41.8%) were successfully treated with laser peripheral iridotomy alone in the long term. Sixty-four eyes (58.1%) developed an increase in intraocular pressure (requiring treatment) on follow-up, of which 49 eyes developed an increase in intraocular pressure within the first 6 months after acute primary angle-closure. Thirty-six eyes (32.7%) eventually underwent trabeculectomy because of uncontrolled intraocular pressure despite laser and medical therapy.

CONCLUSIONS: In this study of Asian eyes, a high proportion (58.1%) of eyes with acute primary angle-closure developed an increase in intraocular pressure on long-term follow-up after resolution of the acute attack, despite the presence of a patent laser peripheral iridotomy. These results suggest a racial difference in the outcome of laser peripheral iridotomy after acute primary angle-closure in Asians, compared with Caucasians. Because a majority of eyes that develop an increase in intraocular pressure do so within the first 6 months of presentation, close monitoring of intraocular pressure is advised in the follow-up of patients with acute primary angle-closure.

El texto completo de este artículo está disponible en PDF.

Esquema


© 2001  Elsevier Science Inc. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 131 - N° 1

P. 7-12 - janvier 2001 Regresar al número
Artículo precedente Artículo precedente
  • Effects of laser in situ keratomileusis (LASIK) on the corneal endothelium 3 years postoperatively
  • Michael J Collins, Jonathan D Carr, R.Doyle Stulting, Ramzy G Azar, George O Waring, Robert E Smith, Keith P Thompson, Henry F Edelhauser
| Artículo siguiente Artículo siguiente
  • Mini-trabeculectomy in eyes with high risk of scarring: midterm follow-up
  • Avinoam Ophir, Joseph Pikkel

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.