Suscribirse

THREE-DIMENSIONAL COMPUTED TOMOGRAPHY FOR PLANNING UROLOGIC SURGERY - 08/09/11

Doi : 10.1016/S0094-0143(05)70437-7 
Geoffrey S. Young, MD a, Stuart G. Silverman, MD a, Joachim Kettenbach, MD a, Nobuhiko Hata, MD a, Polina Golland, MD, PhD c, Ferenc A. Jolesz, MD a, Kevin R. Loughlin, MD b, Ron Kikinis, MD a
a Departments of Radiology (GSY, SGS, JK, NH, FAJ, RK) 
b Surgery (KRL), Brigham and Women's Hospital, Harvard Medical School, Boston 
c the Artificial Intelligence Laboratory, Massachusetts Institute of Technology (PG), Cambridge, Massachusetts 

Resumen

The development and marketing of new volumetric computed tomography (CT) scanners in 1990 made it possible to perform three-dimensional (3-D) imaging of the abdomen without respiratory artifacts and with clarity similar to that achieved in the musculoskeletal and central nervous systems by conventional scanners.6 Before 1990, all CT scanners had x-ray tubes that were connected to the machine's gantry by electrical cables. This limited the excursion of the tube in any one direction because continuous rotation would wind the cables into a knot. Thus, conventional CT scanning is performed by executing a series of individual CT scan slices during which patients are instructed to hold their breath. Between scans the table is moved forward a certain distance and the process is repeated. If the breath holds are not identical, the imaged organ or region contains gaps or skip areas. This limitation is termed “respiratory misregistration.” The technical advantage that made volumetric CT possible was the development of a continuously rotating x-ray tube with slip rings. Slip rings are a pair of matched rings on the tube and gantry that can rotate past one another without limit. This allows for continuous rotation of the tube and the ability to perform a continuous x-ray exposure as the patient is moved forward through the CT gantry. The resulting exposure forms a path that looks like a spiral or helix; hence, today volumetric CT scanning often is referred to as “spiral” or “helical” CT. Spiral CT acquires data in a region of interest using a single continuous x-ray exposure that is fast enough to be executed during a single breath hold, as the patient moves through the gantry, so that respiratory misregistration is eliminated. An entire body region is imaged and a continuous volume of CT data obtained. The resulting volumetric CT data set can be used to create axial images at a desired slice thickness and at a desired increment. Standard axial images from spiral CT of the urinary tract have been shown to be helpful in the diagnosis and staging of renal masses and are now routinely used for evaluation of renal lesions.15, 16 However, the same spiral CT data can be reformated in multiple planes or in three dimensions.

Although newer 3-D reconstruction techniques retain more data than did older reformatted display methods, 3-D images cannot contain more information than appropriately filmed axial images from the same source data set. Thus, with the possible exception of CT angiography and future developments in virtual endoscopy, 3-D images, by themselves, are of limited diagnostic utility. However, 3-D imaging of the urinary tract is useful in surgical planning, because it allows surgeons to visualize 3-D anatomic relationships clearly. 3-D images created from the same spiral CT data sets for diagnosis and staging of renal masses have been used to create color-coded 3-D surface renderings of renal masses and surrounding structures for surgical planning of partial nephrectomy.1 A preliminary investigation and one published case report9 have shown that this technique can help the urologist locate small renal masses and can help delineate the relationship between a mass and the urinary collecting system during operative planning. Currently, in addition to standard spiral CT, conventional preoperative assessment of a patient before a partial nephrectomy may include aortography and selective renal angiography to determine the number, location, and pattern of branching of renal vessels. Intravenous pyelography also may be indicated to evaluate the anatomic relationship of any renal masses to the intrarenal collecting system and proximal ureter. Someday, 3-D rendering of the same spiral CT data set used to diagnose the tumor may be able to display the relationship between the tumor and the renal parenchyma, vasculature, and collecting system, thus obviating the need for these additional tests.

El texto completo de este artículo está disponible en PDF.

Esquema


 Address reprint requests to Stuart G. Silverman, MD Department of Radiology Brigham and Women's Hospital Harvard Medical School 45 Francis Street Boston, MA 02115
The authors wish to acknowledge the following grants NIH PO1 CA 67165-01A1 (RK, FAJ), PO1 AG04953-14 (RK), NSF BES-9631710 (RK), DARPA F41624-96-2-0001 (RK, FAJ) and Austrian Science Fund, Project Jo 1315-MED (JK), Japan Society for Promotion of Science, Tokyo, Japan (NH).


© 1998  W. B. Saunders Company. Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 25 - N° 1

P. 103-111 - février 1998 Regresar al número
Artículo precedente Artículo precedente
  • LAPAROSCOPIC SURGERY : Transition to the Future
  • Richard M. Satava, Shaun B. Jones
| Artículo siguiente Artículo siguiente
  • OPEN-CONFIGURATION MR IMAGING, INTERVENTION, AND SURGERY OF THE URINARY TRACT
  • Terence Z. Wong, Stuart G. Silverman, Julia R. Fielding, Clare M.C. Tempany, Kullervo Hynynen, Ferenc A. Jolesz

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.