Computer-controlled minute ventilation in preterm infants undergoing mechanical ventilation - 11/09/11

Doi : 10.1016/S0022-3476(97)70042-8 
Nelson Claure, MS, Tilo Gerhardt, MD, Helmut Hummler, MD, Ruth Everett, BS, Eduardo Bancalari, MD

Abstract

Introduction: Computer-controlled minute ventilation (CCMV) continuously adjusts the ventilator rate to changes in spontaneous respiratory drive and pulmonary mechanics to maintain a preset total minute ventilation. Hypothesis: We hypothesized that CCMV would maintain ventilation and oxygenation with fewer mechanical breaths than conventional intermittent mandatory ventilation in very low birth weight infants. Methods: Very low birth weight infants in clinically stable condition who were undergoing mechanical ventilation were enrolled. The number of mechanical breaths, total and mechanical expiratory minute ventilation, mean airway pressure, oxygen hemoglobin saturation by pulse oximetry, and transcutaneous partial carbon dioxide and partial oxygen tensions were obtained during intermittent mandatory ventilation and CCMV (45 to 60 minutes) and compared by paired t test. Results: Fifteen infants were studied. Birth weight (median, range) was 700 gm (550 to 1205 gm), gestational age 26 weeks (23 to 34 weeks), age 21 days (3 to 50 days). When switched from intermittent mandatory ventilation to CCMV, the number of mechanical breaths was reduced (15 ± 2.8 to 8.6 ± 2.9 breaths per minute, p < 0.001), leading to lower airway pressure (3.97 ± 1.00 to 3.45 ± 1.00 cm H2O, p < 0.001) and lower expiratory minute ventilation generated by the mechanical ventilator (116 ± 31 to 65 ± 28 ml/min per kilogram, p < 0.001), while total expiratory minute ventilation remained unchanged. Mean transcutaneous partial carbon dioxide and oxygen tensions, oxygen hemoglobin saturation, and the time spent within different oxygen hemoglobin saturation ranges did not differ between both ventilatory modes. Conclusion: CCMV maintained adequate ventilation and oxygenation with lower mechanical ventilatory support than IMV. CCMV may reduce barotrauma and chronic lung disease during long-term use.(J Pediatr 1997;131:910-3)

El texto completo de este artículo está disponible en PDF.

Abbreviations : CCMV, Fio2, IMV, P, PEEP, PIP, Spo2, TcPco2, TcPo2, Te, Ti, e, emec, etot, VLBW, VT


Esquema


 From the Division of Neonatology, Department of Pediatrics, University of Miami School of Medicine, Miami, Florida.
 Supported by the University of Miami Project: New Born.
 Reprint requests: Tilo Gerhardt, MD, Professor of Pediatrics, University of Miami School of Medicine, Department of Pediatrics (R-131), PO Box 016960, Miami, FL 33101.
 0022-3476/97/$5.00 + 0 9/22/83225


© 1997  Mosby, Inc. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 131 - N° 6

P. 910-913 - décembre 1997 Regresar al número
Artículo precedente Artículo precedente
  • Thyroid function in children with Cushing's disease before and after transsphenoidal surgery
  • Constantine A. Stratakis, George Mastorakas, Mary-Alexandra Magiakou, Efstathios Papavasiliou, Edward H. Oldfield, George P. Chrousos
| Artículo siguiente Artículo siguiente
  • Transjugular intrahepatic portosystemic shunts (TIPS) in children
  • Melvin B. Heyman, Jeanne M. LaBerge, Kenneth A. Somberg, Philip Rosenthal, Christine Mudge, Ernest J. Ring, John D. Snyder

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.