Suscribirse

Components anteversion in primary cementless THA using straight stem and hemispherical cup: A prospective study in 91 hips using CT-scan measurements - 14/10/11

Doi : 10.1016/j.otsr.2011.02.014 
O. Reikerås , R.B. Gunderson
Orthopaedic and Radiological Departments, Oslo University Hospital, Rikshospitalet, 0027 Oslo, Norway 

Corresponding author. Tel.: +47 23076013; fax: +47 23076010.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Summary

Background

The recommended range of anteversion of the components in total hip arthroplasty (THA) is between 10 and 30°, but the intraoperative estimation of these versions may be inadequate.

Hypothesis

The components anteversion in primary cementless THA using straight stem and hemispherical cup is not significantly different from the native anteversion of the hip joint.

Objectives

To evaluate in a prospective manner the range of anteversion currently achieved in cementless THA.

Patients and methods

Five senior surgeons operated 91 patients with primary cementless THA. We used a straight press fit stem and a hemispherical press fit cup. We aimed to obtain femoral anteversion of 10 to 30°, acetabular anteversion of 10 to 30° and a global combined anteversion of 25 to 55°. Cup position was checked with an impactor-positioner, and stem position was determined with the knee flexed 90°. In all cases we used elevated liners and 28mm diameter ceramic heads. At 3months postoperatively the component versions were measured using a General Electric LightSpeed Pro 16 (Milwaukee, Wi, USA) with the patient in supine position.

Results

Femoral component measurements ranged from 17° of retroversion to 60° of anteversion with a mean of 23.0±11.8°. Similarly, acetabular component version ranged from 28° of retroversion to 46° of anteversion with a mean of 18.5±13.7°. There were no correlations to the native femoral and acetabular versions. Only 55 hips (60.4%) were within the accepted range of 25 to 55° of combined anteversion, but none of the cases dislocated during a follow-up of 2years.

Conclusion

In cementless THA with our operative technique, the intraoperative estimation of femoral and acetabular anteversion, in many cases, resulted to be inadequate in relation to the intended range of 10 to 30° of anteversion.

Level of evidence

Level III, prospective diagnostic.

El texto completo de este artículo está disponible en PDF.

Keywords : Arthroplasty, Component positioning, CT-scan, Hip, Measurement


Esquema


© 2011  Publicado por Elsevier Masson SAS.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 97 - N° 6

P. 615-621 - octobre 2011 Regresar al número
Artículo precedente Artículo precedente
  • Periacetabular cement extrusion in the course of total hip replacement: Incidence and consequences. An analysis from 269 consecutive cemented total hips
  • H. d’Astorg, J. Amzallag, A. Poignard, F. RoudotThoraval, J. Allain
| Artículo siguiente Artículo siguiente
  • Periprosthetic femoral fractures treated by locked plating: Feasibility assessment of the mini-invasive surgical option. A prospective series of 36 fractures
  • M. Ehlinger, P. Adam, A. Di Marco, Y. Arlettaz, B.-K. Moor, F. Bonnomet

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.