Retrieval analysis of squeaking ceramic implants: Are there related specific features? - 25/04/12

Doi : 10.1016/j.otsr.2011.12.003 
C. Chevillotte a, , b , R.T. Trousdale c , K.-N. An d , D. Padgett e , T. Wright e
a T-Pavilion, Department of Orthopaedic Surgery, Edouard-Herriot Hospital, 5, place d’Arsonval, 69437, Lyon cedex 03, France 
b Shocks Biomechanics Research Laboratory, LBMC-INRETS URMT 9406, Claude-Bernard University, Lyon, France 
c Department of Orthopedic surgery, Mayo Clinic, 200, First Street SW, 55902 Rochester, MN, USA 
d Biomechanic laboratory, Mayo Clinic, 200, First street, 55902 Rochester, MN, USA 
e Hospital for Special Surgery, 535, East 70th Street, 10021 New York, USA 

Corresponding author. Tel.: +33 4 72 11 76 33.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Summary

Introduction

Ceramic-on-ceramic total hip arthroplasty is routinely used for young and active patients with end stage of hip osteoarthritis. However, squeaking noise is a recently identified problem with such bearing surface. Many in vivo and in vitro studies have been conducted trying to find the potential causes of this phenomenon. However, we are not aware of any study analyzing retrieved ceramic implants for squeaking.

Hypothesis

Our primary hypothesis was that the surface analysis of retrieved ceramic implants with squeaking would present interesting deteriorations that could explain the squeaking noise.

Materials and methods

Nine retrieved squeaking implants from ceramic-on-ceramic total hip arthroplasty that were retrieved for various reasons (two exclusively for squeaking, four for recurrent dislocation, one for aseptic loosening and two for instability) were analyzed. Implant positioning was calculated, macroscopic damages were noticed and microscopic roughness was analyzed. The retrieved implants were then tested on a hip simulator reproducing flexion/extension motions in several situations in lubricated and non-lubricated conditions in order to reproduce squeaking.

Results

Five cups were considered with borderline insufficient anteversion. Gross impingement damage was visible on seven implants. All the retrieved heads had visible metal transfer on their surface. Eight implants had visible stripe wear. Microscopic analysis showed roughness higher than six microns on the retrieved heads. Squeaking was reproduced in vitro in dry conditions. In lubricated conditions, squeaking did not occur for the retrieved hips.

Discussion

This retrieval analysis suggests that problems of cup orientation and design which can lead to impingement can generate lubrication problems because of metal transfer plus/minus stripe wear which is a common theme in ceramic-on-ceramic bearings that squeak.

Level of evidence

Level IV, retrospective study.

El texto completo de este artículo está disponible en PDF.

Keywords : Squeaking, Total hip arthroplasty, Ceramic, Surface bearing, Metal transfer, Stripe wear


Esquema


© 2012  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 98 - N° 3

P. 281-287 - mai 2012 Regresar al número
Artículo precedente Artículo precedente
  • Joint perception after hip or knee replacement surgery
  • M. Collins, M. Lavigne, J. Girard, P.-A. Vendittoli
| Artículo siguiente Artículo siguiente
  • Proximal femoral nail antirotation (PFN-ATM) fixation of extra-capsular proximal femoral fractures in the elderly: Retrospective study in 102 patients
  • E. Soucanye de Landevoisin, A. Bertani, P. Candoni, C. Charpail, E. Demortiere

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.