Abstract

Study Objectives

Obtaining intravenous (IV) access in the emergency department (ED) can be especially challenging, and physicians often resort to placement of central venous catheters (CVCs). Use of ultrasound-guided peripheral IV catheters (USGPIVs) can prevent many “unnecessary” CVCs, but the true impact of USGPIVs has never been quantified. This study set out to determine the reduction in CVCs by USGPIV placement.

Methods

This was a prospective, observational study conducted in 2 urban EDs. Patients who were to undergo placement of a CVC due to inability to establish IV access by other methods were enrolled. Ultrasound-trained physicians then attempted USGPIV placement. Patients were followed up for up to 7 days to assess for CVC placement and related complications.

Results

One hundred patients were enrolled and underwent USGPIV placement. Ultrasound-guided peripheral IV catheters were initially successfully placed in all patients but failed in 12 patients (12.0%; 95 confidence interval [CI], 7.0%-19.8%) before ED disposition, resulting in 4 central lines, 7 repeated USGPIVs, and 1 patient requiring no further intervention. Through the inpatient follow-up period, another 11 patients underwent CVC placement, resulting in a total of 15 CVCs (15.0%; 95 CI, 9.3%-23.3%) placed. Of the 15 patients who did receive a CVC, 1 patient developed a catheter-related infection, resulting in a 6.7% (95 CI, 1.2%-29.8%) complication rate.

Conclusion

Ultrasound prevented the need for CVC placement in 85% of patients with difficult IV access. This suggests that USGPIVs have the potential to reduce morbidity in this patient population.

El texto completo de este artículo está disponible en PDF.

Esquema


 Previously presented as a poster presentation at the American College of Emergency Physicians Scientific Assembly October 2011, San Francisco, Calif.


© 2012  Elsevier Inc. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 30 - N° 9

P. 1950-1954 - novembre 2012 Regresar al número
Artículo precedente Artículo precedente
  • Initial accuracy of bedside ultrasound performed by emergency physicians for multiple indications after a short training period
  • Juan Torres-Macho, Juan M. Antón-Santos, Isabel García-Gutierrez, María de Castro-García, Sergio Gámez-Díez, Pilar García de la Torre, Gonzalo Latorre-Barcenilla, Yolanda Majo-Carbajo, Juan C. Reparaz-González, Gonzalo García de Casasola, Working Group of Clinical Ultrasound, Spanish Society of Internal Medicine
| Artículo siguiente Artículo siguiente
  • Diagnostic performance of the BinaxNow Influenza A&B rapid antigen test in ED patients
  • Wesley H. Self, Candace D. McNaughton, Carlos G. Grijalva, Yuwei Zhu, James D. Chappell, John V. Williams, H. Keipp Talbot, David K. Shay, Marie R. Griffin

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.