Suscribirse

Head position angles to open the upper airway differ less with the head positioned on a support - 08/12/12

Doi : 10.1016/j.ajem.2012.06.007 
Thomas Mitterlechner, MD a, , Peter Paal, MD a, Lukas Kuehnelt-Leddhin, MD a, Alexander M. Strasak, PhD b, Günther Putz, MD a, Nikolaus Gravenstein, MD c, Achim von Goedecke, MD, MSc d, Volker Wenzel, MD, MSc a
a Department of Anaesthesiology and Critical Care Medicine, Innsbruck Medical University, Anichstrasse 35, 6020 Innsbruck, Austria 
b Department of Medical Statistics, Informatics and Health Economics, Innsbruck Medical, University, Schoepfstraße 41, 6020 Innsbruck, Austria 
c Department of Anesthesiology, University of Florida, Gainesville, FL 32610–0254, USA 
d Department of Anaesthesiology and Critical Care Medicine, County Hospital Steyr, Sierningerstr, 170, 4400 Steyr, Austria 

Corresponding author. Tel.: +43 512 504 80497; fax: +43 512 504 6780497.

Abstract

Introduction

The aim of the study was to assess the effects of positioning the head on a support on “head position angles” to optimally open the upper airway during bag-valve mask ventilation.

Methods

We ventilated the lungs of anesthetized adults with a bag-valve mask and the head positioned with (n = 30) or without a support (n = 30). In both groups, head position angles and ventilation parameters were measured with the head positioned in (1) neutral position, (2) in a position deemed optimal for ventilation by the investigator, and (3) in maximal extension.

Results

Between groups (“head with/without a support”) and between head positions within each group, head position angles and ventilation parameters differed (P < .0001, respectively). However, head position angles and ventilation parameters between head positions differed less “with a support” (P < .001), and ventilation parameters improved with a support compared with the head-without-a-support group (P < .001).

Conclusions

In the head-with-a-support group, when compared with the head-without-a-support group, head position angles differed less, indicating a decreased potential for failure during bag-valve mask ventilation with the head on a support. Moreover, in the head-with-a-support group, ventilation parameters differed less between head positions, and ventilation improved. These findings suggest a potential benefit of positioning the head on a support during bag-valve mask ventilation.

El texto completo de este artículo está disponible en PDF.

Esquema


 This study is registered in ClinicalTrials.gov NCT00869648.
☆☆ Competing interest statement: No author has any financial or personal relationships with other people or organizations that could inappropriately influence this work.


© 2013  Elsevier Inc. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 31 - N° 1

P. 80-85 - janvier 2013 Regresar al número
Artículo precedente Artículo precedente
  • Red cell distribution width as a prognostic marker in patients with community-acquired pneumonia
  • Jae Hyuk Lee, Hea Jin Chung, Kyuseok Kim, You Hwan Jo, Joong Eui Rhee, Yu Jin Kim, Kyeong Won Kang
| Artículo siguiente Artículo siguiente
  • Effects of hypothermia on brain injury assessed by magnetic resonance imaging after cardiopulmonary resuscitation in a porcine model of cardiac arrest
  • Zi-Ren Tang, Chun-Sheng Li, Hong Zhao, Ping Gong, Ming-Yue Zhang, Zhi-Yu Su, Shuo Wang

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.