Suscribirse

Détection écho-Doppler des endofuites de type II après endoprothèses aortiques : intérêt des agents de contraste - 26/11/13

Doi : 10.1016/j.jmv.2013.08.004 
P. Costa a, ⁎ , P. Bureau Du Colombier a, P. Lermusiaux b, c
a Service d’explorations fonctionnelles vasculaires et cardiaques, hôpital Édouard-Herriot, pavillon M, 5, place d’Arsonval, 69437 Lyon cedex 03, France 
b Service de chirurgie vasculaire, hôpital Édouard-Herriot, pavillon M, 5, place d’Arsonval, 69437 Lyon cedex 03, France 
c Université Claude-Bernard Lyon-1, 8, avenue Rockefeller, 69373 Lyon cedex 08, France 

⁎Auteur correspondant. Allée de l’Île-aux-Moineaux, 25000 Besançon, France.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Résumé

Objectif

Les endofuites de type II (EFII) sont définies par une alimentation du sac anévrismal par des collatérales de l’aorte. Elles représentent la complication la plus fréquente des endoprothèses aortiques (EDP) pour anévrisme de l’aorte abdominale (AAA). Nous avons fait l’hypothèse que l’utilisation des agents de contraste en écho-Doppler par un médecin vasculaire entraîné pourrait augmenter la sensibilité de détection des EF II, la tomodensitométrie (TDM) étant l’examen de référence.

Matériel et méthodes

Entre novembre 2010 et février 2013, ont été inclus prospectivement des patients suivis pour endoprothèse. Chaque patient a eu trois méthodes de surveillance : un écho-Doppler standard, un écho-Doppler avec injection de produit de contraste et une TDM. La sensibilité, spécificité et la corrélation avec le coefficient de Kappa ont été déterminées pour évaluer les performances de l’écho-Doppler standard et avec injection de contraste pour dépister les EF II par rapport à la TDM.

Résultats

Soixante écho-Doppler standard et 60 écho-Doppler avec injection ont été comparés à 60 TDM. Dix-neuf EFII ont été dépistées à la TDM, 14 EFII à l’écho-Doppler seul et 15 EFII avec agent de contraste. La sensibilité de détection des EFII par rapport à la TDM par écho-Doppler seul était de 74 % (κ=0,75) et avec agent de contraste de 78 % (κ=0,8). La spécificité des deux méthodes était de 97 %. Il existait une bonne concordance des résultats des écho-Dopplers standards sans contraste (κ=0,75) et avec contraste (κ=0,8) par rapport à la TDM, et il existait une très bonne concordance des résultats entre l’écho-Doppler seul et avec agent de contraste pour détecter les endofuites de type II (κ=0,93). Il n’y a pas eu de différence statistiquement significative entre les sensibilités de l’écho-Doppler standard et avec contraste (p=0,32).

Conclusion

Nos résultats suggèrent que les agents de contraste n’augmentent pas la sensibilité de détection des endofuites de type II par l’écho-Doppler lorsqu’il est réalisé par un médecin vasculaire entraîné.

El texto completo de este artículo está disponible en PDF.

Summary

Objective

Type II endoleaks (EFII) are related to retrograde flow via aorta tributaries. They are the most frequent complication after endovascular aneurysm repair (EVAR). We hypothesized that the use of contrast-enhanced ultrasound (CEUS) by an experienced vascular physician could increase the sensitivity of detecting EFII compared with computed tomography angiography (CTA) taken as the gold standard.

Material and method

From November 2010 to February 2013, patients with EVAR were included prospectively. All patients had a color duplex ultrasound (CDU), CEUS and CTA. Sensitivity, specificity and kappa's coefficient were determined to estimate the performance of CDU and CEUS to assess EFII compared with CTA.

Results

Sixty CDU and 60 CEUS explorations were compared to 60 CTA explorations. Nineteen type EFII were detected by CTA, 14 by CDU and 15 by CEUS. CDU sensitivity was 74% (κ=0.75), and CEUS sensitivity was 78% (κ=0.8). Both tests exhibited 97% specificity. There was good agreement between CDU results (κ=0.75) and CEUS results (κ=0.8) compared with CTA. There was very good agreement between CDU and CEUS results for detection of EFII (κ=0.93). There was no statistically significant difference between the sensitivity of CDU and CEUS (P=0.32).

Conclusion

Our results suggest that contrast enhancement does not increase yield for ultrasound detection of type II endoleaks when performed by an experienced vascular physician.

El texto completo de este artículo está disponible en PDF.

Mots clés : Anévrysme de l’aorte abdominale, Endoprothèse aortique, Tomodensitométrie, Échographie-doppler, Agent de contraste

Keywords : Abdominal aorta aneurysm, Endovascular aneurysm repair, Computed tomography, Duplex ultrasound, Contrast-enhanced ultrasound


Esquema


☆ Il s’agit d’un travail de recherche clinique effectué sur 40 patients.


© 2013  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 38 - N° 6

P. 352-359 - décembre 2013 Regresar al número
Artículo precedente Artículo precedente
  • Faisabilité pratique de l’auto-injection des traitements anticoagulants : l’expérience du réseau GRANTED
  • J. Yver, L. Desbat, E. Nozières, B. Satger, M. Fontaine, S. Blaise, G. Pernod, les membres du réseau GRANTED
| Artículo siguiente Artículo siguiente
  • La connaissance des facteurs de risque cardiovasculaire est-elle meilleure après la survenue d’un évènement ischémique majeur ? Enquête auprès de 135 cas et 260 témoins
  • A.-S. Lensel, P. Lermusiaux, C. Boileau, P. Feugier, A. Sérusclat, Y. Zerbib, J. Ninet

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.