Suscribirse

Tomographie par cohérence optique plein champ des biopsies de la prostate : un pas vers le diagnostic pré-histologique ? - 21/12/13

Doi : 10.1016/j.purol.2013.05.008 
F. Beuvon a, E. Dalimier b, F. Cornud c, N. Barry Delongchamps d,
a Service d’anatomopathologie, hôpital Cochin, université Paris Descartes, 75014 Paris, France 
b Light for Life Technologies (LLTech), Pépinière Paris Santé Cochin, 75014 Paris, France 
c Service de radiologie A, hôpital Cochin, université Paris Descartes, 75014 Paris, France 
d Service d’urologie, hôpital Cochin, université Paris Descartes, 27, rue du Faubourg-Saint-Jacques, 75014 Paris, France 

Auteur correspondant.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

páginas 9
Iconografías 4
Vídeos 0
Otros 0

Résumé

Objectif

Évaluer la valeur diagnostique de la tomographie par cohérence optique plein champ (FFOCT) sur biopsies de la prostate.

Patients et méthode

Huit patients consécutifs soumis à des biopsies de la prostate en raison d’une élévation du PSA ou d’une anomalie au toucher rectal, ont été inclus dans cette étude. Pour chaque patient, une à trois carottes biopsiques ont été analysées en imagerie par cohérence optique plein champ immédiatement après leur prélèvement. Les images obtenues ont été analysées en aveugle par un anatomopathologiste, et classées en trois catégories : tissu non carcinomateux, tissu suspect de malignité et adénocarcinome. Une analyse de corrélation anatomopathologique a été ensuite réalisée.

Résultats

Seize carottes biopsiques ont été imagées avant analyse anatomopathologique. La durée médiane de la technique était de quatre (3–5) minutes. En histologie standard (coloration HES), aucun artefact n’a été noté. Six carottes étaient envahies par un cancer, huit carottes étaient indemnes de cancer, et deux carottes étaient suspectes de cancer sans diagnostic formel. Une analyse immuno-histochimique a confirmé l’existence d’un cancer dans une seule de ces deux carottes. La concordance entre le résultat de l’analyse optique et histologique était correcte dans 13 cas sur 16 (81 %). Les trois cas de discordance diagnostique étaient dus à deux faux négatifs et à un faux positif de l’analyse optique.

Conclusions

La FFOCT des biopsies de la prostate semblait être une technique faisable et donne, dans la majorité des cas, des résultats concordants avec ceux de l’analyse histologique.

El texto completo de este artículo está disponible en PDF.

Summary

Objectives

To evaluate the value of full field optical coherence tomography (FFOCT) for cancer detection on prostate biopsies

Patients and methods

Eight consecutive patients who underwent prostate biopsies for an elevated PSA or suspicious DRE findings were included in the study. For each patient, one to three biopsy cores were imaged with FFOCT immediately after sampling. Images obtained were analyzed by a pathologist blinded to the pathological results, and classified into three categories: non-cancerous tissue, suspicion of malignancy and prostate carcinoma. A pathological correlation analysis was further performed.

Results

Sixteen biopsy cores were analyzed. The median FFOCT procedure time was of 4 (3–5) minutes. No artifact was noted in subsequent pathological analysis. Six cores were involved with cancer and eight cores showed no evidence of cancer. On two cores, diagnosis was uncertain, and immuno-histochemical analysis confirmed cancer involvement in one of them. The agreement rate between standard histological analysis and FFOCT evaluation was of 81% (13/16). The three cases of disagreement were due to one false positive and two false negatives of FFOCT analysis.

Conclusions

FFOCT of prostate biopsy cores seemed to be feasible and to allow concordant results with those of pathological analysis in the majority of the cases.

El texto completo de este artículo está disponible en PDF.

Mots clés : Cancer de la prostate, Biopsies, Histologie, OCT plein champ

Keywords : Prostate cancer, Biopsy, Histology, Full field OCT


Esquema


 Niveau de preuve : 3.


© 2013  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 24 - N° 1

P. 22-30 - janvier 2014 Regresar al número
Artículo precedente Artículo precedente
  • Prélèvement rénal sur donneur décédé par arrêt cardiaque (DDAC) : organisation dans un centre hospitalier non universitaire
  • V. Arnoux, D. Dorez, M. Muller, A. Gignoux, C. Valignat, A. Faucher, E. Dechamboux, A.-S. Gour, D. Jakkel, L. Saint Marcel, N. Terrier, O. Skowron
| Artículo siguiente Artículo siguiente
  • Suivi longitudinal de l’IPSS dans les cinq ans suivant un traitement d’un cancer de prostate localisé : analyse globale et par type de traitement
  • R. Lorion, S. Guérif, P. Bouchaert, O. Celhay, B. Doré, G. Fromont, J. Irani

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
La compra de artículos no está disponible en este momento.

¿Ya suscrito a @@106933@@ revista ?

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.