Resumen

Objective

Interventional catheterism can be an alternative to surgery for PDA closure. With the new device PDA ADO IISA, we evaluate feasibility and safety to close PDA in low birth weight infants<2500g when indicated.

Methods

In presence of Clinical signs, ultrasounds (US) defined hemodynamic significant PDA (HSPDA) by mean arterial velocity into pulmonary artery branch>45cm/sec, absence or reverse flow in the middle cerebral artery, renal and mesenteric arteries and DA diameter. Interventional catheterism was proposed vs. surgery to the parents. Babies are anesthetized and intubated. The procedure is done under fluoroscopy without contrast and US. Through femoral vein access a 4F catheter is positioned in descending aorta and occluder precisely opened under horizontal X-ray and US. Temperature is kept>36°C during the procedure.

Results

fourteen infants had PDA closure. Mean weight was 1674g (880–2480), the series started at the highest weight. Mean diameter of the duct was 3,3mm (2,2–4) and length 5,8mm (2–11). PDA ADO IISA used were 3×4 (2) 4×2 (2), 4×4 (4), 4×6 (2), 5×2 (3) and 5×6 (1). Two were repositioned and one changed to increase diameter. Mean duration of the entire procedure was 29minutes (10–90). X-ray exposure was 12min (3–24) and dose 1,5gray/cm2 (0.2–4). Two transitional paraprothetic shunts closed spontaneously after few days. One premature infant already in renal failure, died ten days later despite ductal closure. In the others, the follow-up showed improvement in cerebral and pulmonary blood flows without any hemodynamic problems such as observed after surgical procedures.

Conclusion

This preliminary series showed feasibility and safety when combining X-ray and US to close a PDA with PDA ADO IIAS.

El texto completo de este artículo está disponible en PDF.

Esquema


© 2014  Publicado por Elsevier Masson SAS.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 107 - N° 8-9

P. 487 - août 2014 Regresar al número
Artículo precedente Artículo precedente
  • A new percutaneous pulmonary valve implantation technique for complex right ventricular outflow tracts: The ‘Folded Melody® Valve’
  • Z. Jalal, S. Malekzadeh-Milani, M. Hofbeck, K. Al Najashi, J.B. Thambo, Y. Boudjemline
| Artículo siguiente Artículo siguiente
  • Evaluation of knowledge level of adolescents and adults with congenital heart disease: Effectiveness of a structured CHD education program in adolescents
  • M. Ladouceur, R. Cheurfi, C. Pagnon, S. Cohen, F. Bajolle, L. Iserin, P. Jourdain, D. Bonnet

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2025 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.