Suscribirse

Robotic phrenic nerve harvest: A feasibility study in a pig model - 11/10/14

Doi : 10.1016/j.main.2014.07.006 
P. Porto de Melo a, b, c, H. Miyamoto d, e, T. Serradori f, G. Ruggiero Mantovani g, J. Selber h, S. Facca d, W.-D. Xu i, N. Santelmo j, P. Liverneaux d,
a Center for Advanced Studies in Orthopedics and Neurosurgery, São Paulo, Brazil 
b Neurosurgery Department, São Paulo Military Área Hospital, Brazilian Army, São Paulo, Brazil 
c Institute of Education and Sciences, German Hospital Oswaldo Cruz, São Paulo, Brazil 
d Department of Hand Surgery, Strasbourg University Hospitals, FMTS, Strasbourg University, 10, avenue Baumann, 67403 Illkirch cedex, France 
e Department of Orthopaedic Surgery, University of Tokyo, Tokyo, Japan 
f General and digestive Departement, University Hospital of Nancy, 54511 Nancy, France 
g São Paulo Hand Center, Hospital Beneficência Portuguesa de São Paulo, São Paulo, Brazil 
h MD Anderson Center, Houston, TX, USA 
i Department of Hand Surgery, Huashan Hospital, Fudan University, Shanghai, China 
j Department of Thoracic Surgery, Strasbourg University Hospitals, FMTS, Strasbourg University, 1, place de l’Hôpital, 67000 Strasbourg cedex, France 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

páginas 5
Iconografías 3
Vídeos 0
Otros 0

Abstract

The aim of this study was to report on the feasibility of robotic phrenic nerve harvest in a pig model. A surgical robot (Da Vinci S™ system, Intuitive Surgical®, Sunnyvale, CA) was installed with three ports on the pig's left chest. The phrenic nerve was transected distally where it enters the diaphragm. The phrenic nerve harvest was successfully performed in 45 minutes without major complications. The advantages of robotic microsurgery for phrenic nerve harvest are the motion scaling up to 5 times, elimination of physiological tremor, and free movement of joint-equipped robotic arms. Robot-assisted neurolysis may be clinically useful for harvesting the phrenic nerve for brachial plexus reconstruction.

El texto completo de este artículo está disponible en PDF.

Résumé

Le but de cette étude était de rapporter la faisabilité du prélèvement du nerf phrénique avec un robot sur un modèle porcin. Un robot chirurgical (système da Vinci S™, Intuitive Surgical®, Sunnyvale, CA) a été installé avec trois trocarts sur l’hémithorax gauche d’un cochon. Le nerf phrénique a été sectionné distalement, là où il pénètre dans le diaphragme. Le prélèvement du nerf phrénique a été réalisé avec succès en 45 minutes sans complications majeures. Les avantages de la microchirurgie robotisée pour le prélèvement du nerf phrénique sont la mise à l’échelle du mouvement jusqu’à 5 fois, l’élimination de tremblement physiologique, et la liberté de mouvements des articulations des bras robotiques. La neurolyse robot-assistée peut être cliniquement utile pour le prélèvement du nerf phrénique dans la chirurgie de réparation des lésions du plexus brachial.

El texto completo de este artículo está disponible en PDF.

Keywords : Brachial plexus, Da Vinci robot, Phrenic nerve, Robot-assisted microsurgery, Telemicrosurgery

Mots clés : Plexus brachial, Robot Da Vinci, Nerf phrénique, Microchirurgie robotique, Télémicrochirurgie


Esquema


© 2014  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 33 - N° 5

P. 356-360 - octobre 2014 Regresar al número
Artículo precedente Artículo precedente
  • Proximal interphalangeal joint arthroplasty with Neuflex® implants: Relevance of the volar approach and early rehabilitation
  • S. Bouacida, C. Lazerges, B. Coulet, M. Chammas
| Artículo siguiente Artículo siguiente
  • Radial artery pseudoaneurysm: A rare complication after arthroscopic treatment of a volar wrist ganglion in a hemophilia patient
  • C. Clerico, M. Benatar, C. Dumontier

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
La compra de artículos no está disponible en este momento.

¿Ya suscrito a @@106933@@ revista ?

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.