Suscribirse

Locking plate fixation versus antegrade nailing of 3- and 4-part proximal humerus fractures in patients without osteoporosis. Comparative retrospective study of 63 cases - 06/12/14

Doi : 10.1016/j.otsr.2014.09.021 
G. Boudard a, , G. Pomares a , L. Milin a , I. Lemonnier b , H. Coudane a , D. Mainard c , J.-P. Delagoutte a
a Service de Chirurgie Arthroscopique Traumatologique Orthopédique de l’Appareil Locomoteur, CHU de Nancy, Hôpital Central, 29, avenue du Maréchal-Delattre-de-Tassigny, 54000 Nancy, France 
b Service d’Épidémiologie et Évaluation Clinique, CHU de Nancy, Hôpitaux de Brabois, allée du Morvan, 54500 Vandœuvre-lès-Nancy, France 
c Service de Chirurgie Orthopédique et Traumatologique, CHU de Nancy, Hôpital Central, 29, avenue du Maréchal-Delattre-de-Tassigny, 54000 Nancy, France 

Corresponding author. Tel.: +33 06 73 95 53 03.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Introduction

There is no consensus on the treatment of proximal humeral fractures. The goal of the present retrospective observational study was to compare functional and radiological results and complications of internal fixation using locking plates versus antegrade nailing in the treatment of non-osteoporotic Neer classification 3- and 4-part fractures after a least 1year of follow-up.

Material and methods

Internal fixation was performed in 67 fractures (1 bilateral): 35 by locking plate (1 lost to follow-up, 1 deceased) and 32 by intramedullary nailing (2 lost to follow-up) between January 1st, 2004 and December 31st, 2010. Thus, the study included 33 plates (21 3-part and 12 4-part fractures) and 30 nails (21 3-part and nine 4-part fractures). Final functional assessment was based on the Oxford, Constant, Relative Constant and QuickDASH scores and percentage of handicap. Radiological follow-up included immediate postoperative, 6weeks, 3months and 1year AP and Lamy lateral views. All complications were recorded prospectively.

Results

Mean Oxford, Constant, Relative Constant and QuickDASH scores and percentage of disability for the plate and nail groups respectively were: 23.8 vs. 23.3, 59.7 vs. 60 6, 73.5 vs 79.3, 20.9 vs 21.0, 22.6 vs 22.6. Multivariate analysis did not show any significant difference in functional scores or quality of reduction: final unsatisfactory reduction on AP view, 30.3 vs. 36.7%; lateral view, 3.2 vs. 10.0%; greater tuberosity, 9.1 vs. 16.7%. Four-part fracture (P<0.05), frontal reduction defect at follow-up (P<0.05) or greater tuberosity defect (P>0.05) had negative impacts on functional scores. The complication rates corresponded to those in the literature and did not differ between the techniques (P=0.1901) except for three infections in the plate group.

Discussion-Conclusion

Internal fixation is the treatment of choice for 3- and 4-part fractures in non-osteoporotic patients. Although no difference was found in the present study between locking plate and intramedullary nailing, the former seems to be less well adapted and more aggressive.

Type of study

Retrospective observational study.

Level of evidence

Level 4.

El texto completo de este artículo está disponible en PDF.

Keywords : Shoulder, Proximal humerus fractures, 3- and 4- part fractures, Locking plates, Intramedullary nailing


Esquema


© 2014  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 100 - N° 8

P. 917-924 - décembre 2014 Regresar al número
Artículo precedente Artículo precedente
  • AKILE™ total ankle arthroplasty: Clinical and CT scan analysis of periprosthetic cysts
  • J. Lucas y Hernandez, O. Laffenêtre, E. Toullec, V. Darcel, D. Chauveaux
| Artículo siguiente Artículo siguiente
  • Percutaneous Tenolig® repair under intra-operative ultrasonography guidance in acute Achilles tendon rupture
  • S. Lacoste, J.M. Féron, B. Cherrier

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.