Suscribirse

Development and validation of an analytical method for quantification of 15 non-tricyclic antidepressants in serum with UPLC-MS/MS - 07/05/15

Doi : 10.1016/j.toxac.2015.03.083 
S. Resende 1, , C. Deschrijver 2, E. Van De Velde 2, A. Verstraete 1, 2
1 Department of Clinical Chemistry, Microbiology and Immunology, Ghent University 
2 Department of Laboratory Medicine, Ghent University Hospital, Ghent, Belgium 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

páginas 2
Iconografías 0
Vídeos 0
Otros 0

Resumen

Objective

Non-tricyclic antidepressants are often encountered in overdose cases, and for some of them therapeutic monitoring might be warranted [1]. Therefore we developed and validated an ultra-performance liquid chromatography-tandem mass spectrometry method for the quantification of 15 common non-tricyclic antidepressants in serum: citalopram, desmethylcitalopram, desmethylfluoxetine, desmethylvenlafaxine, duloxetine, fluoxetine, fluvoxamine, melitracen, mianserin, mirtazapine, paroxetine, reboxetine, sertraline, trazodone and venlafaxine. The selected pharmaceuticals represent (nor) tramadol (added because of the desmethylvenlafaxine interference) and all the non-tricyclic antidepressants available in Belgium.

Methods

Serum samples (250μL) were precipitated with methanol and acetonitrile containing 5ng of the internal standards: mirtazapine-D4, paroxetine-D5, reboxetine-D6 and venlafaxine-D6. The supernatant was evaporated at 56°C under a flow of nitrogen and reconstituted in 100μL of 50:50 methanol:water with 2mM ammonium acetate. Five microliters was injected and the target analytes were separated on a 100×2.1mm ACQUITY BEH C18 column (Waters, Zellik, Belgium) using a Waters ACQUITY Ultra-Performance Liquid Chromatography system. The analytes were eluted within 7.5min, using a gradient of 2mM ammonium acetate and 0.1% formic acid in water and in methanol at a flow rate of 0.4mL/min. Quantification was performed on a Waters triple quadrupole ACQUITY TQD using multiple reaction monitoring (MRM) in positive mode (2 MRMs per analyte). A six-point calibration curve was used to cover a large concentration range from 10ng/mL to 1000ng/mL. The method was validated based on the Scientific Working Group for Forensic Toxicology (SWGTOX) guideline.

Results

No interfering signals from matrix, internal standard or tricyclic antidepressant drugs were found. Limits of quantification and limits of detection ranged from 10 to 85ng/mL and 2.0 to 28ng/mL, respectively. Ion suppression from matrix effects varied from 36 to 108% for the compounds and 47 to 102% for the internal standards. Process efficiency varied from 22 to 106%. Intra- and interassay imprecision varied from 3.5 to 12.3% and 3.1 to 12.3%, respectively. The bias of the assay was lower than 15% for all the compounds, except the lowest concentrations of desmethylcitalopram, tramadol and trazodone (bias<20%). No carryover was observed.

Conclusion

Good validation performance was obtained thanks to the use of selected deuterated internal standards that adjusted for all of the compounds, to compensate for the global method variability. This method is therefore suitable for both therapeutic drug monitoring and quantification in suspected overdose cases.

El texto completo de este artículo está disponible en PDF.

Esquema


© 2015  Publicado por Elsevier Masson SAS.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 27 - N° 2S

P. S54-S55 - juin 2015 Regresar al número
Artículo precedente Artículo precedente
  • Dosage simultané de 15 produits stupéfiants dans les cheveux par LC-MS/MS avec extraction en ligne
  • H. Grison-Hernando, C. Renaud, G. Deslandes, A. Pineau, E. Dailly, R. Bouquie, C. Azoulay-Fauconnier, P. Jolliet, C. Monteil-Ganiere
| Artículo siguiente Artículo siguiente
  • Matrix using SPE and LC-MS/MS
  • A. Leffler, S. Huq, S. Sadjadi, S. Orlowicz

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
La compra de artículos no está disponible en este momento.

¿Ya suscrito a @@106933@@ revista ?

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.