Suscribirse

Computed tomography-gastro-colonography for percutaneous endoscopic gastrostomy using a helical computed tomography - 18/06/15

Doi : 10.1016/j.amjsurg.2014.10.029 
Kazuya Kato, M.D., Ph.D. a, , Masahiko Taniguchi, M.D., Ph.D. b, Yoshiaki Iwasaki, M.D., Ph.D. c, Keita Sasahara, R.T. a, Atsushi Nagase, M.D. d, Kazuhiko Onodera, M.D., Ph.D. e, Minoru Matsuda, M.D., Ph.D. f, Yuhei Inaba, M.D., Ph.D. g, Takako Kawakami, M.D. a, Mineko Higuchi, R.N. a, Yuko Kobashi, M.D., Ph.D. h, Hiroyuki Furukawa, M.D., Ph.D. b
a Department of Surgery, Pippu Clinic, 2-10, 1 cyome Nakamachi, Pippu, Town Kamikawa-gun, Hokkaido 078-0343, Japan 
b Department of Surgery, Asahikawa Medical University, 1-1, 2-1, Midorigaoka, Asahikawa City 078-8510, Japan 
c Department of Gastroenterology and Hepatology, Okayama University, 2-5-1, Shikata Town, Okayama City, Okayama 700-8558, Japan 
d Department of Surgery, Asahikawa Medical Center, 4048, 7 cyome, Hanasaki-cyo, Asahikawa City 070-8644, Japan 
e Department of Surgery, Hokuyu Hospital, 5-1, 6-6 Higashi-Sappro, Shiroishi-ku, Sapporo City 003-0006, Japan 
f Department of Surgery, Nihon University, 1-8-13 Surugadai Kanda, Chiyoda-ku, Tokyo 010-8309, Japan 
g Department of Internal Medicine, Asahikawa Medical University, 1-1, 2-1, Midorigaoka, Asahikawa City 078-8510, Japan 
h Department of Radiology, Jikei University, 3-25-8, Nishi-shinbashi, Minato-ku, Tokyo 105-8461, Japan 

Corresponding author. Tel.: +81-166-85-2222; fax: +81-166-58-9008.

Abstract

Background

Despite the widespread use of percutaneous endoscopic gastrostomy (PEG) tubes, their placement may be associated with a variety of complications, including gastrocolic fistula.

Methods

In total, 48 individuals underwent computed tomography-gastro-colonography (CT-GC)-guided PEG placement. Study end points included success of CT-GC, inability to thread the PEG tube, the eventual tube location, tube adjustments needed, adverse events, operating time, and PEG tube-related infection.

Results

A successful CT-GC was achieved in all 48 patients (100%), and we successfully used a standard PEG technique to place the gastrostomy tube in 44 patients (92%). In 4 patients (8%), the laparoscopic-assisted PEG technique was used because the transverse colon became interposed between the abdominal wall and the anterior wall of the stomach. The overall procedure-related minor complication rate was 8%.

Conclusion

CT-GC is an optional method for the estimation of intra-abdominal, anatomical orientations that may minimize the risk of complications before PEG placement.

El texto completo de este artículo está disponible en PDF.

Keywords : Percutaneous endoscopic gastrostomy, Iatrogenic colic perforation, Gastrocolic fistula, CT-gastrography, CT-colonography


Esquema


 There were no relevant financial relationships or any sources of support in the form of grants, equipment, or drugs.
 The authors declare no conflicts of interest.
 Written informed consent was obtained from the patients' relatives for the publication of this report and any accompanying images. Copies of the written consent are available for review by the Editor-in-Chief of this journal.
 Dr Kato is accepting full responsibility for the conduct of the study.


© 2015  Elsevier Inc. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 210 - N° 2

P. 374-381 - août 2015 Regresar al número
Artículo precedente Artículo precedente
  • Abdominal wall reconstruction using a combination of free tensor fasciae lata and anterolateral thigh myocutaneous flap: a prospective study in 16 patients
  • Yang Lv, Dongsheng Cao, Fangfang Guo, Yunliang Qian, Chen Wang, Danru Wang
| Artículo siguiente Artículo siguiente
  • Quality and improvement
  • Mark A. Malangoni

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.