Suscribirse

Can the Windkessel Hypothesis Explain Delayed Intraparenchymal Haemorrhage After Flow Diversion? A Case Report and Model-Based Analysis of Possible Mechanisms - 31/07/15

Doi : 10.1016/j.hlc.2015.02.001 
Alim P. Mitha, MD SM a, b, , Jonathan P. Mynard, PhD c, d, 1, John A. Storwick a, Zaher I. Shivji, BSc a, John H. Wong, MD MSc a, b, William Morrish, MD b
a Department of Clinical Neurosciences, and 
b Department of Radiology, Foothills Medical Centre, Calgary, Alberta, Canada 
c Biomedical Simulation Laboratory, Department of Mechanical & Industrial Engineering, University of Toronto, Toronto, Canada 
d Heart Research, Clinical Sciences, Murdoch Children's Research Institute, Melbourne, Australia 

Corresponding author at: Department of Clinical Neurosciences, Foothills Medical Centre, 1403-29th Street N.W., Calgary, Alberta T2N-2T9 Tel.: +403 944-4550; fax: +403 944-8712

Resumen

Background

Delayed ipsilateral intraparenchymal haemorrhage is a recently recognised complication after endovascular flow diversion for intracranial aneurysms. Although the mechanism of this phenomenon is not understood, one proposed explanation (the windkessel hypothesis) is that removal of aneurysmal compliance increases distal pulse pressure.

Methods

We present a case of delayed haemorrhage after placement of a Pipeline stent, discuss the proposed mechanisms, and describe a novel electrical analogue model that was used to evaluate the likely haemodynamic effect of stent placement.

Results

Model-based analysis suggests that stenting is not likely to produce a significant change in distal pulse pressure. Moreover, basic fluid dynamics principles suggest that a local reduction in disturbed flow in the region of the aneurysm could produce only a minor increase in distal pressure (a few mmHg), which is unlikely to be the main cause of the observed haemorrhage.

Conclusion

The windkessel hypothesis is unlikely to explain the occurrence of delayed ipsilateral intraparenchymal haemorrhage after flow diversion; however, other mechanisms involving altered haemodynamics distal to the treated aneurysm may play a role. Further studies involving the assessment of haemodynamic changes after flow diversion would be useful to understand, and eventually mitigate, this currently unpredictable risk.

El texto completo de este artículo está disponible en PDF.

Keywords : Flow diversion, Intracranial aneurysm, Intraparenchymal haemorrhage, Mathematical model, Windkessel Effect, Pipeline stent


Esquema


© 2015  Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 24 - N° 8

P. 824-830 - août 2015 Regresar al número
Artículo precedente Artículo precedente
  • Evaluation of Markers of Inflammation and Oxidative Stress in COPD Patients with or without Cardiovascular Comorbidities
  • Marcin Ka?mierczak, Maciej Ciebiada, Anna P?kala-Wojciechowska, Maciej Paw?owski, Agnieszka Nielepkowicz-Go?dzi?ska, Adam Antczak
| Artículo siguiente Artículo siguiente
  • Clinical Exercise Stress Testing in Adults (2014)
  • David Colquhoun, Ben Freedman, David Cross, Ben Fitzgerald, Brett Forge, David L. Hare, James Tatoulis, John Wicks, Andrew Wilson, Robert Zecchin

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.