Abbonarsi

Does arthrodesis of the first metatarsophalangeal joint correct the intermetatarsal M1M2 angle? Analysis of a continuous series of 208 arthrodeses fixed with plates - 06/10/15

Doi : 10.1016/j.otsr.2015.06.021 
F. Dalat a, , F. Cottalorda b, M.-H. Fessy a, c, J.-L. Besse a, c
a Service de chirurgie orthopédique, traumatologique et de médecine du sport, hospices civils de Lyon, centre hospitalier Lyon-Sud, 69495 Pierre-Bénite cedex, France 
b Service de chirurgie orthopédique et traumatologique, CHU Gabriel Montpied, Clermont-Ferrand, France 
c Laboratoire de biomécanique et mécanique des chocs, université Lyon 1, IFSTTAR, LBMC UMR-T 9406, 69675 Bron cedex, France 

Corresponding author. Service de chirurgie orthopédique, traumatologique et de médecine du sport, centre hospitalier Lyon-Sud, chemin du Grand-Revoyet, 69495 Pierre-Bénite cedex, France. Tel.: +04 7886 5930; fax: +04 7886 5934.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Introduction

First-ray metatarsophalangeal arthrodesis is a classic surgical procedure in the treatment of severe hallux valgus, hallux rigidus, revision surgery, and inflammatory arthritis. The objective of this study was to verify if metatarsophalangeal plate arthrodesis could correct the M1M2 intermetatarsal angle.

Material and methods

This prospective and continuous series (June 2007 to March 2011) included 208 patients (48% severe and/or arthritic hallux valgus, 18% hallux rigidus, 16% rheumatoid forefoot, 13% surgical revision of the first ray, 5% hallux varus), with a mean age of 62.4±9.9 years (range, 19–87 years). All the patients were operated on by a senior surgeon with the same technique: spherical avivement of the joint surfaces using reamers, osteosynthesis with an anatomic plate (Fyxis-Biotech™) in Ti.6Al.4V alloy prebent to 5° with a phalangeal arm to receive an oblique metatarsophalangeal screw in compression, in addition to four 2.7-mm nonlocking dorsal screws. The full-scale preoperative and intraoperative angle measurements were taken on AP and lateral X-rays of the weightbearing foot, as related to the etiology and the severity of the preoperative metatarsus varus (M1M2<15°, M1M2 15–19°, M1M220°). The statistical analysis was done using the StatView software.

Results

The mean follow-up was 18.6±12.4 months (range, 2–76 months). Nearly all of the arthrodesis patients (97%) achieved bone union, and 5% of the plates were removed. The M1P1angle decreased from 33.8±19.7° (range, −45° to –67°) preoperatively to 13.3±5.3° (range, 0–32°) at the last follow-up, and the M1M2angle from 14.2±5.4°(range, 0–26°) to 6.5±2.3° (range, 0–12°). The preoperative M1M2angle was <15° in 97 patients, 15–19° for 78 patients, and ≥20° for the 33 others; at the last follow-up it was 5.8±2.1° (range, 0–10°), 6.7±2.2° (0–10°), and 8.1±2.4° (3–12°), respectively. No correction of the metatarsus varus was demonstrated in relation to etiology. The M1M2angle was >10° in only two patients (one case of rheumatoid arthritis and one case of severe hallux valgus): 0.9%.

Discussion

These results show that isolated metatarsophalangeal arthrodesis of the first ray can correct metatarsus varus even in substantial deformations in any etiology.

Level of proof

Level II cohort study.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Hallux, Metatarsophalangeal arthrodesis, M1M2angle, M1P1angle


Mappa


© 2015  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 101 - N° 6

P. 709-714 - Ottobre 2015 Ritorno al numero
Articolo precedente Articolo precedente
  • Actifit® scaffold implantation: Influence of preoperative meniscal extrusion on morphological and clinical outcomes
  • B. Faivre, H. Bouyarmane, G. Lonjon, P. Boisrenoult, N. Pujol, P. Beaufils
| Articolo seguente Articolo seguente
  • Clinical application of radial magnetic resonance imaging for evaluation of rotator cuff tear
  • H. Honda, T. Morihara, Y. Arai, M. Horii, H. Ito, R. Furukawa, Y. Kida, T. Sukenari, K. Ikoma, R. Oda, Y. Yamada, H. Fujiwara, T. Kubo

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2024 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.