Abbonarsi

Preoperative planning for accurate glenoid component positioning in reverse shoulder arthroplasty - 21/04/17

Doi : 10.1016/j.otsr.2016.12.019 
J. Berhouet a, b, , L.V. Gulotta a, b, D.M. Dines a, E. Craig a, R.F. Warren a, D. Choi c, X. Chen c, A. Kontaxis b
a Hospital for Special Surgery, Department of Sports Medicine and Shoulder, 535 E 70th St., New York, NY 10021, USA 
b Hospital for Special Surgery, The Leon Root, Motion Analysis Laboratory, 510 E 73rd St., New York, NY 10021, USA 
c Hospital for Special Surgery, Biomechanical Laboratory, 510 E 73rd St., New York, NY 10021, USA 

Corresponding author at: Hospital For Special Surgery, Department of Sports Medicine and Shoulder, 535 E 70th St., New York, NY 10021, USA.Hospital For Special Surgery, Department of Sports Medicine and Shoulder535 E 70th St.New YorkNY10021USA

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Background

Glenoid component positioning in reverse shoulder arthroplasty (RSA) is challenging. Patient-specific instrumentation (PSI) has been advocated to improve accuracy, and is based on precise preoperative planning. The purpose of this study was to determine the accuracy of glenoid component positioning when only the glenoid surface is visible, compared to when the entire scapula is visible on a 3D virtual model.

Methods

CT scans of 30 arthritic shoulders were reconstructed in 3D models. Two surgeons then virtually placed a glenosphere component in the model while visualizing only the glenoid surface, in order to simulate typical intraoperative exposure (“blind 3D” surgery). One surgeon then placed the component in an ideal position while visualizing the entire scapula (“visible 3D” surgery). These two positions were then compared, and the accuracy of glenoid component positioning was assessed in terms of correction of native glenoid version and tilt, and avoidance of glenoid vault perforation.

Results

Mean version and tilt after “blind 3D” surgery were +1.4° (SD 8.8°) and +7.6° (SD 6°), respectively; glenoid vault perforation occurred in 17 specimens. Mean version and tilt after “visible 3D” surgery were +0.3° (SD 0.8°) and +0.1° (SD 0.5°), respectively, with glenoid vault perforation in 6 cases. “Visible 3D” surgery provided significantly better accuracy than “blind 3D” surgery (P<0.05).

Conclusion

When the entire scapula is used as reference, accuracy is improved and glenoid vault perforation is less frequent. This type of visualization is only possible with pre-operative 3D CT planning, and may be augmented by PSI.

Level of evidence

Basic science study. Level III.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Reverse shoulder arthroplasty, Glenoid component positioning, Accuracy, CT-assisted surgery, Preoperative planning, Patient-specific instrumentation


Mappa


© 2017  Pubblicato da Elsevier Masson SAS.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 103 - N° 3

P. 407-413 - Maggio 2017 Ritorno al numero
Articolo precedente Articolo precedente
  • Hawkins’ type-II talar fracture with subtalar dislocation: A very unusual combination
  • R. Gérard, N. Kerfant, G. Dubois de Mont Marin, R. Stern, M. Assal
| Articolo seguente Articolo seguente
  • Results and limitations of humeral head resurfacing: 105 cases at a mean follow-up of 5 years
  • K. Soudy, C. Szymanski, C. Lalanne, C. Bourgault, A. Thiounn, A. Cotten, C. Maynou

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2024 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.