Abbonarsi

Fat suppression at three-dimensional T1-weighted MR imaging of the hands: Dixon method versus CHESS technique - 05/01/18

Doi : 10.1016/j.diii.2017.09.004 
T. Kirchgesner , V. Perlepe , N. Michoux , A. Larbi , B. Vande Berg
 Musculoskeletal Imaging Unit, cliniques universitaires Saint-Luc, université catholique de Louvain, institut de recherche expérimentale et clinique (IREC), 10, avenue Hippocrate, 1200 Brussels, Belgium 

Corresponding author at: Cliniques universitaires Saint-Luc, Medical imaging department, Musculoskeletal imaging unit, 10, avenue Hippocrate, 1200 Brussels, Belgium.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Highlights

Dixon yields effective fat suppression at 3D T1-weighted MRI of the hands.
SNR is higher with Dixon than with CHESS at 3D T1-weighted MR imaging of the hands.

Il testo completo di questo articolo è disponibile in PDF.

Abstract

Purpose

To compare the effectiveness of fat suppression and the image quality of the Dixon method with those of the chemical shift-selective (CHESS) technique in hands of normal subjects at non-enhanced three-dimensional (3D) T1-weighted MR imaging.

Materials and methods

Both hands of 14 healthy volunteers were imaged with 3D fast spoiled gradient echo (FSPGR) T1-weighted Dixon, 3D FSPGR T1-weighted CHESS and 3D T1-weighted fast spin echo (FSE) CHESS sequences in a 1.5T MR scanner. Three radiologists scored the effectiveness of fat suppression in bone marrow (EFSBM) and soft tissues (EFSST) in 20 joints per subject. One radiologist measured the signal-to-noise ratio (SNR) in 10 bones per subject. Statistical analysis used two-way ANOVA with random effects (P<0.0083), paired t-test (P<0.05) and observed agreement to assess differences in effectiveness of fat suppression, differences in SNR and interobserver agreement.

Results

EFSBM was statistically significantly higher for the 3D FSPGR T1-weighted Dixon than for the 3D FSPGR T1-weighted CHESS sequence and the 3D FSE T1-weighted CHESS sequence (P<0.0001). EFSST was statistically significantly higher for the 3D FSPGR T1-weighted Dixon than for the 3D FSPGR T1-weighted CHESS sequence (P<0.0011) and for the 3D FSE T1-weighted CHESS sequence in the axial plane (P=0.0028). Mean SNR was statistically significantly higher for 3D FSPGR T1-weighted Dixon sequence than for 3D FSPGR T1-weighted CHESS and 3D FSE T1-weighted CHESS sequences (P<0.0001).

Conclusion

The Dixon method yields more effective fat suppression and higher SNR than the CHESS technique at 3D T1-weighted MR imaging of the hands.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : MRI, Fat, Dixon, IDEAL, Hands

Abbreviations : CHESS, EFSBM, EFSST, FSE, FSPGR, ROI, SNR


Mappa


© 2017  Éditions françaises de radiologie. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 99 - N° 1

P. 23-28 - Gennaio 2018 Ritorno al numero
Articolo precedente Articolo precedente
  • Expanding role of percutaneous cholecystostomy and interventional radiology for the management of acute cholecystitis: An analysis of 144 patients
  • D. Kim, S.I. Iqbal, H.K. Ahari, C.P. Molgaard, S. Flacke, B.D. Davison
| Articolo seguente Articolo seguente
  • T1-weighted parenchyma attenuated inversion recovery: A novel sequence that improves contrast ratio of enhancing brain lesions
  • A. Batouli, E. Kanal, A. Gholamrezanezhad, M. Spearman

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2024 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.