Abbonarsi

Loss of radial height in extra-articular distal radial fracture following volar locking plate fixation - 24/08/21

Doi : 10.1016/j.otsr.2021.102842 
Ming Fai Cheng a, b, Chao-Ching Chiang a, b, Chun-Cheng Lin a, b, Ming-Chau Chang a, b, Chien-Shun Wang a, b,
a Department of Orthopedics and Traumatology, Taipei Veterans General Hospital and national Yang Ming University, Taipei, Taiwan 
b Department of Orthopedic Surgery, School of Medicine, National Yang-Ming University, Taipei, Taiwan 

Corresponding author.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Background

Radial height is an important prognostic factor in treating distal radius fracture. However, does further collapse of radial height in distal radius fractures after with volar locking plate fixation have a great impact on the prognosis? The present study aimed to elucidate radial height loss and determine the associated risk factors after open reduction and internal fixation with volar locking plate in patients with extra-articular distal radius fractures.

Hypothesis

Patients with radial height collapse after fracture reduction and internal fixation with a volar locking plate may have poor outcomes.

Methods

Data of 87 patients (21 male) undergoing surgery for acute extra-articular distal radius fractures (AO: 23-A2 or 23-A3) between February 2014 and July 2016 were evaluated retrospectively. Patients were divided into two groups by radial height loss. Potential risk factors were tested by Pearson correlation coefficients. Stepwise multiple regression logistic analysis determined significant independent risk factors for extra-articular distal radius fractures. Clinical evaluation was performed by the same surgeon by determining wrist ROM. Grip strength was measured with a Jamar dynamometer and compared with non-affect wrist in percentage. In addition, all the patients were asked to grade modified Mayo wrist score and Visual Analogue Scale (VAS) score. These findings were recorded postoperative 1 year of follow-up.

Results

Mean radial height loss was 1.3±0.9mm. Age (ß=0.002, p=0.003), postoperative ulnar-positive deformity (ß=0.107, p<0.001), DEXA (ß=−0.015, p=0.008), and shortest diameter of distal fracture fragment in AP and lateral views (ß=−0.050, p=0.037; ß=−0.080, p=0.043) were significantly associated with radial height loss. As for the outcome of clinical prognosis, though radial height collapse group had poorer wrist range of motion, there was no statistical difference. Besides, there were no significant differences in grips strength and VAS score between these two groups. However, in regards of modified Mayo wrist score, the percentage of patients with poor outcomes is significant higher in radial height collapse group (p=0.039). Moreover, all patients with poor outcomes in radial height collapse groups were older than 65-year-old.

Discussion

Radial height loss is noted in patients undergoing open reduction and internal fixation with volar locking plate for extra-articular distal radius fractures. Risk factors for radial height collapse include advanced age, poor bone quality, shortest distance between fracture site and articular surface and postoperative ulnar-positive deformity.

Level of evidence

IV; non-comparative prospective study.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Radial height, Extra-articular distal radius fracture, Volar locking plate


Mappa


© 2021  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 107 - N° 5

Articolo 102842- Settembre 2021 Ritorno al numero
Articolo precedente Articolo precedente
  • Denervation of the proximal interphalangeal joint: Results from 54 cases in 42 patients
  • Lisa Servasier, Jacky Laulan, Emilie Marteau, Guillaume Bacle
| Articolo seguente Articolo seguente
  • Comparative study between fixed-angle and polyaxial screws in distal radius fixation with two volar locking plates
  • Álvaro Toro-Aguilera, Pablo Martínez-Galarza, Pilar Camacho-Carrasco, Miguel Caballero, Josep M. Segur

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2024 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.