Cataractes congénitales : correction de l’aphaquie par lentilles de contact rigides - 09/10/12

Doi : 10.1016/j.jfo.2012.04.003 
C. Loudot , F. Jourdan, C. Benso, D. Denis
Le médival, place Général-de-Gaulle, 83160 La Valette, France 

Auteur correspondant.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Résumé

But

Décrire le suivi et évaluer le résultat fonctionnel d’une adaptation en lentilles de contact rigides à haute perméabilité à l’oxygène pour la correction de l’aphaquie après chirurgie de cataracte congénitale.

Patients et méthode

Vingt-trois yeux de 17 enfants de 3,5 mois d’âge médian [3jours ; 36 mois], opérés de cataracte congénitale sans implantation avec adaptation en lentille Menicon® matériau Z, ont été étudiés. Quatre critères ont été étudiés lors du suivi à huit jours, 15jours, un mois, six mois et un an : les caractéristiques d’adaptation, la manipulation de la lentille, l’intégrité oculaire et l’intégrité de la lentille. Parallèlement, les résultats fonctionnels (acuité visuelle, bilan oculomoteur) et différents facteurs pronostic (pathologies associées, âge de chirurgie, densité de la cataracte, uni/bilatéralité, complications postopératoires) ont été évalués. Une rééducation rigoureuse systématique de l’amblyopie a été effectuée.

Résultats

À l’examen d’un mois, 60 % des parents savaient manipuler la lentille. Trois échecs, sur un an de suivi, ont été imputables à des difficultés de manipulation. En un an, une complication infectieuse a été détectée. Le matériau de la lentille à présenté une bonne résistance (lentille cassée dans 9 % des cas à un mois) et un faible encrassement (absence de dépôts ou faibles dans 95 % des cas à un mois). Au niveau fonctionnel dans la population d’enfants en âge de coopérer, la mesure d’acuité visuelle est supérieure à 3/10e pour neuf sur 12 yeux, dont cinq yeux à 10/10e. Au niveau de l’oculomotricité, 12 cas (70,6 %) de strabisme ont été notés en postopératoire (dix cas d’ésotropie, deux cas d’exotropie). Les facteurs prédictifs de bonne acuité visuelle concordaient avec ceux retrouvés dans la littérature : cataracte partielle, cataracte bilatérale, et absence de trouble oculomoteur postopératoire.

Conclusion

Les caractéristiques du matériau des lentilles rigides à haute perméabilité permettent une adaptation efficace, peu risquée chez l’enfant. Elles représentent une alternative intéressante face à l’implantation primaire lors de la chirurgie de la cataracte congénitale.

Il testo completo di questo articolo è disponibile in PDF.

Summary

Purpose

To describe follow-up and evaluate functional results of rigid gas-permeable contact lens wear for the correction of aphakia in infants after surgery for congenital cataract.

Patients and methods

This retrospective study was performed on 23 eyes of 17 children (12 boys and five girls), between three days and 36 months of age (median 3.5 months), undergoing cataract extraction without primary intraocular lens implantation and fitted only with Menicon® Z material contact lenses. Initial fitting visits included history and family education. Subsequent examinations were performed at eight days, 15 days, 1 month, 6 months and 1 year. The four main parameters studied were fit characteristics, ease of manipulation, ocular integrity and lens integrity. Concurrently, functional results (visual acuity, oculomotor balance) and various prognostic factors (associated pathology, age at time of surgery, cataract density, unilaterality versus bilaterality, postoperative complications) were evaluated. Rigorous systematic amblyopia rehabilitation was performed.

Results

At the one-month exam, 60% of parents demonstrated proficiency with manipulating the lens. On one-year follow-up, three cases of failure were attributable to difficulties with lens manipulation. At one year, one infectious complication was detected. The lens material demonstrated good resistance to breakage (9% at one month) and only a mild tendency toward deposits (few or no deposits in 95% of cases at 1 month). With regard to visual outcome, among the children old enough to cooperate, visual acuity was better than 3/10 for nine out of 12 eyes, of which five eyes were 10/10. With regard to alignment, we noted 12 cases (70.6%) of strabismus postoperatively (ten esotropia, two exotropia). The factors predictive of good visual acuity correlated with those described in the literature: partial cataract, bilateral cataract, and absence of postoperative oculomotor disturbance.

Conclusion

The characteristics of rigid gas-permeable contact lenses provide safety and efficacy in aphakic infant eyes. They represent an attractive alternative to primary intraocular lens implantation in congenital cataract.

Il testo completo di questo articolo è disponibile in PDF.

Mots clés : Lentille rigide perméable aux gaz, Cataracte congénitale, Aphaquie

Keywords : Rigid gas-permeable contact lens, Congenital cataract, Aphakia


Mappa


© 2012  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 35 - N° 8

P. 599-605 - Ottobre 2012 Ritorno al numero
Articolo precedente Articolo precedente
  • Relations entre les paramètres de la réfraction : sphère, cylindre et axe
  • O. Touzeau, T. Gaujoux, J. Bullet, C. Allouch, V. Borderie, L. Laroche
| Articolo seguente Articolo seguente
  • Aspects évolutifs de la rétine en coupe OCT spectral domain lors des oblitérations artérielles rétiniennes
  • P.-L. Cornut, J. Bieber, S. Beccat, V. Fortoul, M. Poli, A. Feldman, P. Denis, C. Burillon

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2024 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.