Purpose

We performed a prospective arthroscopic study to explore the variability of the posterior labrum glenoid insertion. We aimed to classify the insertions and to explore whether these insertions can be identified by pre-operative arthro-CT scan.

Patients and methods

From January to December 2011, 86 patients were prospectively included in the current study. During arthroscopy, anterior labrum was evaluated and posterior labrum was assessed in 3 different locations: superior, medial, and inferior. For each segment, the labrum was considered normally inserted (directly to the glenoid cartilage), medialized (inserted at the posterior part of the glenoid bone, without direct contact with the cartilage), torn (macroscopic degenerative changes, tears, fragments) or absent (agenesis). Imaging was analyzed segment by segment by an experienced osteoarticular radiologist, using the same classification.

Results

Four types of posterior labrum insertions were identified. Type 1, 60% of the cases, corresponded to a posterior labrum totally inserted in the glenoid, with direct contact with the cartilage. Type 2, 20% of the cases, represented medialized insertion of the superior segment. Type 3, 15% of the cases, represented an associated medialization of the superior and medial segment of the posterior labrum. Type 4 is a medialized insertion of the all-posterior labrum. Fifty-six shoulders were used for arthro-CT and arthroscopy correlation: for the superior segment (n=22/56), the sensitivity of arthro-CT to identify an abnormal insertion when the labrum is medialized was 68.18%, specificity 70.59%, positive predictive value (PPV) 60%, and negative predictive value (NPV) 77.42%. For the medial segment (n=16/56), the sensitivity of arthro-CT to identify an abnormal insertion when the labrum is medialized was 81.25%, specificity 57.50%, PPV 43.33% and NPV 88.46%. For the inferior segment (n=5/56), the sensitivity was 100%, specificity 47.60%, PPV 15.63% and NPV 100%.

Conclusion

The current study points out the high variability of shoulder posterior labrum glenoid insertion, and thus the risk of misdiagnosis with posterior labral tears, especially in posterior instability and also the risk of considering as labral lesions some non-pathological aspects.

Level of evidence

Level III. Anatomic prospective study.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Posterior labrum, Labral tear, Posterior instability, Imaging, Dislocation, Fibrocartilage


Mappa


© 2014  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 100 - N° 2

P. 171-174 - Aprile 2014 Ritorno al numero
Articolo precedente Articolo precedente
  • Coracoacromial ligament section under ultrasonographic control: A cadaveric study on 20 cases
  • S. Delforge, B. Lecoq, C. Hulet, C. Marcelli
| Articolo seguente Articolo seguente
  • Outcomes from surgical treatment of middle-third clavicle fractures non-union in adults: A series of 21 cases
  • A. Faraud, N. Bonnevialle, C. Allavena, H. Nouaille Degorce, P. Bonnevialle, P. Mansat

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2024 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.