Abbonarsi

Improving BCI performance through co-adaptation: Applications to the P300-speller - 26/02/15

Doi : 10.1016/j.rehab.2014.10.006 
Jérémie Mattout a, b, , Margaux Perrin a, b, Olivier Bertrand a, b, Emmanuel Maby a, b
a Brain Dynamics and Cognition Team, Lyon Neuroscience Research Center, INSERM U1028-CNRS, UMR5292, 69000 Lyon, France 
b University Lyon 1, 69000 Lyon, France 

Corresponding author at: Centre de recherche en neurosciences de Lyon, CHS Le Vinatier, bâtiment 452, 95, boulevard Pinel, 69500 Bron, France. Tel.: +33 4 72 13 89 07; fax: +33 4 72 13 89 01.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

A well-known neurophysiological marker that can easily be captured with electroencephalography (EEG) is the so-called P300: a positive signal deflection occurring at about 300ms after a relevant stimulus. This brain response is particularly salient when the target stimulus is rare among a series of distracting stimuli, whatever the type of sensory input. Therefore, it has been proposed and extensively studied as a possible feature for direct brain-computer communication. The most advanced non-invasive BCI application based on this principle is the P300-speller. However, it is still a matter of debate whether this application will prove relevant to any population of patients. In a series of recent theoretical and empirical studies, we have been using this P300-based paradigm to push forward the performance of non-invasive BCI. This paper summarizes the proposed improvements and obtained results. Importantly, those could be generalized to many kinds of BCI, beyond this particular application. Indeed, they relate to most of the key components of a closed-loop BCI, namely: improving the accuracy of the system by trying to detect and correct for errors automatically; optimizing the computer's speed-accuracy trade-off by endowing it with adaptive behavior; but also simplifying the hardware and time for set-up in the aim of routine use in patients. Our results emphasize the importance of the closed-loop interaction and of the ensuing co-adaptation between the user and the machine whenever possible. Most of our evaluations have been conducted in healthy subjects. We conclude with perspectives for clinical applications.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Brain-Computer Interfaces, P300-Speller, Error potentials, Feedback Related Negativity, Optimal stopping, Motivation


Mappa


© 2015  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 58 - N° 1

P. 23-28 - Febbraio 2015 Ritorno al numero
Articolo precedente Articolo precedente
  • Thought-based row-column scanning communication board for individuals with cerebral palsy
  • Reinhold Scherer, Martin Billinger, Johanna Wagner, Andreas Schwarz, Dirk Tassilo Hettich, Elaina Bolinger, Mariano Lloria Garcia, Juan Navarro, Gernot Müller-Putz
| Articolo seguente Articolo seguente
  • BCI in patients with disorders of consciousness: Clinical perspectives
  • Jacques Luauté, Dominique Morlet, Jérémie Mattout

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2024 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.