S'abonner

7096 Interventional endoscopy and ercp under mr guidance - preliminary experiments in an animal model. - 20/03/14

Doi : 10.1016/S0016-5107(00)14767-4 
Thomas Roesch, Thomas Merl, Michael Roettinger, Martin Neumann, Klaus Egger, Alexander Meining, Norbert Weigert, Hermann Helmberger, Paul Gerhardt, Hubertus Feussner, Meinhard Classen
 MR-Guided Endotherapy Working Group, Dept of Internal Medicine II, Tech Univ, Munich, Germany 
 Dept of Radiology, Tech Univ, Munich, Germany 
 Dept of Surg, FA Univ, Erlangen, Germany 
 Dept of Surg, Tech Univ Muenchen, Munich, Germany. 

Résumé

Background:Interventional endoscopy including ERCP has been performed under endoscopic and/or fluoroscopic monitoring for gastrointestinal and pancreatobiliary interventions. Saving radiation as well as improving targeting and visualizing of surrounding structures were the main aims of our first experiments in MR-guided therapeutic endoscopy. Methods:The Erlangen training model for interventional endoscopy was used for the experiments with 4 stomach and 2 whole upper abdominal organ sets (including liver and biliary system. One pig stomach carried a spontaneous 5 cm tumor, in the other stomach specimens, tumors were created by fibrin glue injection, polyurethane injection, or banding with tumor sizes between 5 and 15 mm.Two specimens with native bile ducts were used for MR-guided biliary interventions. Accessories used were nitinol baskets, snares and teflon wires. MR machines used for the experiments were the Siemens Magnotom open gantry 0.2 Tesla for the GI experiments and the Philipps ACS NT closed gantry 1.5 Tesla for biliary experiments. Results: With both machines, the endoscope was mainly visible in intragastric fluid; attempts to visualize the endoscope in air using various catheters (filled with gadolinium) or guidewires/probes failed; a gadolinium filled balloon with a diameter of 1 cm around the endoscope tip was the only way to localize the instrument tip. The open system (heavily weighted T2 FLAIR sequences, acquisition times 0.5 - 1.5 minutes) was used for visualization of intragastric tumors which could be seen down to the size of 5 mm. Fibrin glue was less effective than polyurethane and banding in creating visible tumors. Using faster image sequences deteriorated the image. Baskets and snares were partially visible when placed around tumors. For visualization of the biliary system, the open system did not yield sufficient images and therefore the closed system (heavily weighted T2 sequences) was necessary, where the endoscope tip in the duodenum and a papillotome in the CBD could be seen. Conclusions:Sophisticated imaging (preferentially real-time) of smaller structures for delicate therapeutic interventions under MR control (e.g. MR-guided ERCP) will probably require the use of closed MR systems which then have to be short enough for performing endoscopy in an adequate way. Open systems could be used for intermittent monitoring and localization of endoluminal procedures, but acquisition time has to be reduced.

Le texte complet de cet article est disponible en PDF.

© 2000  American Society for Gastrointestinal Endoscopy. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 51 - N° 4P2

P. AB266 - avril 2000 Retour au numéro
Article précédent Article précédent
  • 7095 Description of endoscopic stricturotomy and pyloric myotomy in patients with mechanical gastric outlet obstruction.
  • Charles W. Randall, Anitha Nair
| Article suivant Article suivant
  • 7097 Prospective evaluation of the safety of percutaneous transhepatic cholangioscopy.
  • Dong Wan Seo, Sung Koo Lee, Myung Hwan Kim, Kyo Sang Yoo, Young Il Min

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.