A comparative study between two different 3D reconstruction methods by bi-planar radiographic in upright posture: Biomod 3sand sterEOS® - 26/09/15

Doi : 10.1016/j.rehab.2015.07.217 
A. Jirot, Dr, A. Hocquelet, Dr, C. Reaux, M. De Seze, Dr
 CHU de Bordeaux, Bordeaux, France 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Résumé

Objectives

This study aims to evaluate the repeatability and reproducibility of two different methods of 3D reconstruction of the spine sterEOS® and BIOMODTM3S.

Materials and methods

Repeatability and reproducibility study. Three observers performed the reconstructions: a radiologist, a X-ray technologist and a rehabilitation specialist, inexperienced in X-ray reading. The observers made these reconstructions with each modality: sterEOS® and BIOMODTM3S. The parameters investigated were Cobb angle, sagittal parameters (cyphosis, lordosis), determination of apical and junctional vertebrae, axial rotation of the apical vertebra, pelvic parameters and time of reconstruction. Statistical analyses were done using Intraclass Correlation Coefficient (ICC) for reproducibility and Student's t test for time of reconstruction.

Results

We analyzed X-rays of 44 women (71%) and 18 men (29%) with a mean age of 44±20.8. The repeatability was correct, good or excellent depending on observer. The reproducibility inter-observer was correct to excellent (ICC 0.73–0.96) for every parameter except the axial rotation of the apical vertebrae and the determination of levels of junctional and apical vertebrae. The reproducibility of the axial rotation of apical vertebrae was low to good with BIOMODTM3S (ICC 0.15–0.81; ESM=7.5°). The reproducibility of the determination of levels of junctional and apical vertebrae was low to excellent with sterEOS® (ICC 0.36–0.90). With sterEOS®, the reproducibility was impaired by the inexperienced observator for some parameters. The 3D reconstructions with sterEOS® was significantly faster than with BIOMODTM3S (10.8min vs 14.2min, p<0.05).

Discussion

Parameters’ reproducibility is different depending on the system. The 3D reconstruction with sterEOS® is faster than with BIOMODTM3S. The reproducibility of BIOMODTM3S is less influenced by observator's experience

Le texte complet de cet article est disponible en PDF.

Keywords : 3D Reconstruction, Spine, Scoliosis, X-ray


Plan


© 2015  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 58 - N° S1

P. e89 - septembre 2015 Retour au numéro
Article précédent Article précédent
  • Tumor necrosis factor-alpha blockade in recurrent and disabling chronic sciatica associated with post-operative peridural lumbar fibrosis: Results of a two-year, double-blind, placebo randomized controlled study
  • C. Nguyen, C. Palazzo, S. Grabar, A. Feydy, K. Sanchez, N. Zee, L. Quinquis, M. Ben Boutieb, M. Revel, M.M. Lefèvre-Colau, S. Poiraudeau, F. Rannou
| Article suivant Article suivant
  • Assessing the perception of movements in subjects with chronic pain using altered virtual feedback
  • C. Mercier, M. Roosink, B.J. Mcfadyen, L.J. Hébert, P.L. Jackson, L.J. Bouyer

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.