S'abonner

Long Term Outcomes Following Freestyle Stentless Aortic Bioprosthesis Implantation: An Australian Experience - 09/12/15

Doi : 10.1016/j.hlc.2015.05.011 
Andrew G Sherrah, MBBS a, b, Richmond W Jeremy, PhD FRACP a, b, c, Rajesh Puranik, PhD FRACP a, c, Paul G Bannon, PhD FRACS a, b, d, e, P Nicholas Hendel, FRACS b, d, Matthew S Bayfield, FRACS b, d, Michael K Wilson, FRACS b, d, f, Peter W Brady, FRACS g, David Marshman, FRACS g, Manu N Mathur, FRACS g, R John Brereton, FRACS g, James R Edwards, FRACS h, Robert G Stuklis, FRACS h, Michael Worthington, FRACS h, Michael P Vallely, PhD FRACS a, b, d, f,
a Sydney Medical School, University of Sydney, Sydney, NSW, Australia 
b The Baird Institute for Applied Heart and Lung Surgical Research, Sydney, NSW, Australia 
c Department of Cardiology, Royal Prince Alfred Hospital, Sydney, NSW, Australia 
d Department of Cardiothoracic Surgery, Royal Prince Alfred Hospital, Sydney, NSW, Australia 
e Institute of Academic Surgery, Royal Prince Alfred Hospital, Sydney, NSW, Australia 
f Australian School of Advanced Medicine, Macquarie University, Sydney, NSW, Australia 
g Department of Cardiothoracic Surgery, Royal North Shore Hospital, Sydney, NSW, Australia 
h Darcy Sutherland Cardiothoracic Surgical Unit, Royal Adelaide Hospital, Adelaide, SA, Australia 

Corresponding author at: Suite 209, 100 Carillon Avenue, Newtown NSW 2042, Australia. Tel.: +61 2 9422 6090; fax: +61 2 9422 6099

Résumé

Background

The Freestyle stentless bioprosthesis (FSB) has been demonstrated to be a durable prosthesis in the aortic position. We present data following Freestyle implantation for up to 10 years post-operatively and compare this with previously published results.

Methods

A retrospective cohort analysis of 237 patients following FSB implantation occurred at five Australian hospitals. Follow-up data included clinical and echocardiographic outcomes.

Results

The cohort was 81.4% male with age 63.2±13.0 years and was followed for a mean of 2.4±2.3 years (range 0-10.9 years, total 569 patient-years). The FSB was implanted as a full aortic root replacement in 87.8% patients. The 30-day all cause mortality was 4.2% (2.0% for elective surgery). Cumulative survival at one, five and 10 years was 91.7±1.9%, 82.8±3.8% and 56.5±10.5%, respectively. Freedom from re-intervention at one, five and 10 years was 99.5±0.5%, 91.6±3.7% and 72.3±10.5%, respectively. At latest echocardiographic review (mean 2.3±2.1 years post-operatively), 92.6% had trivial or no aortic regurgitation. Predictors of post-operative mortality included active endocarditis, acute aortic dissection and peripheral vascular disease.

Conclusions

We report acceptable short and long term outcomes following FSB implantation in a cohort of comparatively younger patients with thoracic aortic disease. The durability of this bioprosthesis in the younger population remains to be confirmed.

Le texte complet de cet article est disponible en PDF.

Keywords : Aortic valve, Heart valve prosthesis, Bioprosthesis, Aorta, Thoracic, Aortic Aneurysm


Plan


© 2015  Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 25 - N° 1

P. 82-88 - janvier 2016 Retour au numéro
Article précédent Article précédent
  • The Effect of Treatment Delays Associated with Inpatient Inter-hospital Transfer from Peripheral to Tertiary Hospitals for the Surgical Treatment of Cardiology Patients
  • S. Prabhu, D. Blusztein, D. Jackson, M. Sharma, S. Arunothayaraj, M.B. Stokes, A. Kras, H. Yi, L. Kong, K. Haji, K. Peck, J.M. Casan, G.D. Toogood
| Article suivant Article suivant
  • Prevention of Sternal Wound Infections by use of a Surgical Incision Management System: First Reported Australian Case Series
  • Scott Jennings, Jim Vahaviolos, Justin Chan, Michael G Worthington, Robert G Stuklis

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.