S'abonner

0041: Contrast-induced microvascular dilatation: implications for fractional flow reserve measurements - 12/02/16

Doi : 10.1016/S1878-6480(16)30029-5 
Julien Adjedj ((1)), , Gabor Toth ((1)), Mariano Pellicano ((1)), Guiseppe Di Gioia ((1)), Angela Ferrara ((1)), Vincent Flore ((1)), Nils Johnson ((2)), Olivier Muller ((3)), Emanuele Barbato ((3)), Bernard de Bruyne ((3))
(1) Centre Cardiovasculaire Aalst, Aalst, Belgique 
(2) Weatherhead PET Center for Preventing and Reversing Atherosclerosis, Houston, Texas, Etats-Unis 
(3) Hôpital Cantonal Universitaire Vaudois, Cardiologie, Lausanne, Suisse 

*Corresponding author:

Résumé

Background

The use of adenosine is sometimes considered as a limiting factor for of fractional flow reserve (FFR) measurements. The present study sought to quantify the potential of contrast medium (CM) to induce microvascular dilatation as assessed by the changes in Doppler flow velocity measurements.

Methods

In 30 patients, Doppler-derived flow velocity measurements were obtained in 10 right coronary arteries (RCA) and 20 left coronary arteries (LCA) free of significant stenosis. Flow velocity was measured at baseline and after 8mL intracoronary (IC) bolus administrations of arterial blood at body temperature, saline and CM compared to intracoronary boluses of adenosine at room temperature. The hyperemic value was expressed in percent of the maximum flow velocity reached in a given artery (Q/Qmax, %). To translate the IC adenosine dose into its effect on FFR, a model based on standard coronary physiology linked the degree of hyperemia to the relative distal coronary pressure (Pd/Pa).

Results

Doppler flow velocity varied among 8mL IC boluses of arterial blood, saline and contrast (p<0.001), and all pairwise comparisons were significant (p<0.001 for blood and contrast; p=0.041 for saline and blood; and p=0.013 for saline and contrast). Hyperemic response after injection of 8mL of CM reached 59±17% of that achieved maximum hyperemia. While Baseline, arterial blood and saline achieved respectively 38±12%, 45±14% and 51±14% of Q/Q max. The incidence of transient atrio ventricular blocks was 38% after injection of 200 μg, while it was not observed withcm. According to our theoretical model, whencm reach 59±17% of that achieved maximum hyperemia after adenosine in Doppler flow velocity it correspond to a Pd/Pa ratio of 0.85, where FFR is 0.79 and the resting Pd/Pa is 0.90.

Conclusion

CM reaches approximately 60% of the maximal flow velocity as compared to Adenosine IC. This corresponds to a difference of only 6% when “translated” in terms of FFR.

Le texte complet de cet article est disponible en PDF.

© 2016  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 8 - N° 1

P. 10 - janvier 2016 Retour au numéro
Article précédent Article précédent
  • 0013: Feasibility, image quality and radiation dose of Coronary CT Angiography (CCTA) in patients with atrial fibrillation using a new generation 256 Multi-Detector CT (MDCT)
  • Laurent Macron, Jean-Louis Sablayrolles, Jacques Feignoux
| Article suivant Article suivant
  • 0090: Comparison between non-invasive coronary flow reserve, instantaneous wave-free ratio, and fractional flow reserve, to assess the functional significance of LAD stenosis of intermediate severity
  • Patrick Meimoun, Dorothée Ardourel, Jerome Clerc, Frederic Elmkies, Anne Luycx-Bore, Sonia Martis, Hamdane Zemir, Jacques Boulanger

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.