S'abonner

Evaluation of trainees’ ability to perform obstetrical ultrasound using simulation: challenges and opportunities - 31/03/16

Doi : 10.1016/j.ajog.2015.10.932 
Gihad E. Chalouhi, MD a, c, , Valeria Bernardi, MD b, c, Alexandra Gueneuc, MD a, c, Isabelle Houssin, MS a, c, Julien J. Stirnemann, MD, PhD a, c, Yves Ville, MD, PhD a, c
a Department of Obstetrics and Fetal Medicine, Necker-Enfants-Malades Hospital, APHP, Université Paris Descartes, Sorbonne Paris Cité, Paris, France 
b Department of Women and Children Health, Universita degli Studi di Padova, Padova, Italy 
c SimECHOle, Ecole de simulation pour l'enseignement et le perfectionnement en échographie, Paris, France 

Corresponding author: Gihad E. Chalouhi, MD.

Abstract

Background

Evaluation of trainee’s ability in obstetrical ultrasound is a time-consuming process, which requires involving patients as volunteers. With the use of obstetrical ultrasound simulators, virtual reality could help in assessing competency and evaluating trainees in this field.

Objective

The objective of the study was to test the validity of an obstetrical ultrasound simulator as a tool for evaluating trainees following structured training by comparing scores obtained on obstetrical ultrasound simulator with those obtained on volunteers and by assessing correlations between scores of images and of dexterity given by 2 blinded examiners.

Study Design

Trainees, taking the 2013 French national examination for the practice of obstetrical ultrasound were asked to obtain standardized ultrasound planes both on volunteer pregnant women and on an obstetrical ultrasound simulator. These planes included measurements of biparietal diameter, abdominal circumference, and femur length as well as reference planes for cardiac 4-chamber and outflow tracts, kidneys, stomach/diaphragm, spine, and face. Images were stored and evaluated subsequently by 2 national examiners who scored each picture according to previously established quality criteria. Dexterity was also evaluated and subjectively scored between 0 and 10. The Raghunathan’s modification of Pearson, Filon’s z, Spearman’s rank correlation, and analysis of variance tests were used to assess correlations between the scores by the 2 examiners and scores of dexterity and also to compare the final scores between the 2 different methods.

Results

We evaluated 29 trainees. The mean dexterity scores in simulation (6.5 ± 2.0) and real examination (5.9 ± 2.3) were comparable (P = .31). Scores with an obstetrical ultrasound simulator were significantly higher than those obtained on volunteers (P = .027). Nevertheless, there was a good correlation between the scores of the 2 examiners judging on simulation (R = 0.888) and on volunteers (R = 0.873) (P = .81).

Conclusion

An obstetrical ultrasound simulator is as good a method as volunteer-based examination for evaluating practical skills in trainees following structured training in obstetrical ultrasound. The threshold for success/failure should, however, be adapted as candidates obtain higher scores on the simulator. Advantages of the obstetrical ultrasound simulator include the absence of location and time constraints without the need to involve volunteers or to interfere with the running of ultrasound clinics. However, an obstetrical ultrasound simulator still lacks the ability to evaluate the trainees’ ability to interact with patients.

Le texte complet de cet article est disponible en PDF.

Key words : evaluation, medical education, simulation, training, ultrasound


Plan


 The authors report no conflict of interest.
 Cite this article as: Chalouhi GE, Bernardi V, Gueneuc A, et al. Evaluation of trainees’ ability to perform obstetrical ultrasound using simulation: challenges and opportunities. Am J Obstet Gynecol 2016;214:525.e1-8.


© 2016  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 214 - N° 4

P. 525.e1-525.e8 - avril 2016 Retour au numéro
Article précédent Article précédent
  • Universal cervical length screening: implementation and outcomes
  • Lorene A. Temming, Jennifer K. Durst, Methodius G. Tuuli, Molly J. Stout, Jeffrey M. Dicke, George A. Macones, Alison G. Cahill
| Article suivant Article suivant
  • Use of Maternal Early Warning Trigger tool reduces maternal morbidity
  • Laurence E. Shields, Suzanne Wiesner, Catherine Klein, Barbara Pelletreau, Herman L. Hedriana

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.