S'abonner

Endoscopic intestinal bypass creation by using self-assembling magnets in a porcine model - 31/05/16

Doi : 10.1016/j.gie.2015.10.023 
Marvin Ryou, MD 1, A. Tony Agoston, MD 2, Christopher C. Thompson, MD, MSc, FACG, FASGE 1,
1 Division of Gastroenterology, Brigham and Women’s Hospital, Harvard Medical School, Boston, Massachusetts, USA 
2 Department of Pathology, Brigham and Women’s Hospital, Harvard Medical School, Boston, Massachusetts, USA 

Reprint requests: Christopher C. Thompson, MD, MSc, FACG, FASGE, Division of Gastroenterology, Brigham and Women’s Hospital, 75 Francis St., Boston, MA 02115.Division of Gastroenterology, Brigham and Women’s Hospital75 Francis St.BostonMA 02115

Abstract

Background and Aims

A purely endoluminal method of GI bypass would be desirable for the treatment of obstruction, obesity, or metabolic syndrome. We have developed a technology based on miniature self-assembling magnets that create large-caliber anastomoses (Incisionless Anastomosis System [IAS]). The aim of this study was to evaluate procedural characteristics of IAS deployment and long-term anastomotic integrity and patency.

Methods

We performed a 3-month survival study of Yorkshire pigs (5 interventions, 3 controls). Intervention pigs underwent simultaneous enteroscopy/colonoscopy performed with the animals under intravenous sedation. The IAS magnets were deployed and coupled with reciprocal magnets under fluoroscopy. Every 3 to 6 days pigs underwent endoscopy until jejunocolonic anastomosis (dual-path bypass) creation and magnet expulsion. Necropsies and histological evaluation were performed. The primary endpoints were technical success; secondary endpoints of anastomosis integrity, patency, and histological characteristics were weight trends.

Results

Under intravenous sedation, endoscopic bypass creation by using IAS magnets was successfully performed in 5 of 5 pigs (100%). Given porcine anatomy, the easiest dual-path bypass to create was between the proximal jejunum and colon. The mean procedure time was 14.7 minutes. Patent, leak-free anastomoses formed by day 4. All IAS magnets were expelled by day 12. All anastomoses were fully patent at 3 months with a mean diameter of 3.5 cm. The mean 3-month weight was 45 kg in bypass pigs and 78 kg in controls (P = .01). At necropsy, adhesions were absent. Histology showed full re-epithelialization across the anastomosis without fibrosis or inflammation.

Conclusion

Large-caliber, leak-free, foreign body–free endoscopic intestinal bypass by using IAS magnets can be safely and rapidly performed in the porcine by model using only intravenous sedation.

Le texte complet de cet article est disponible en PDF.

Abbreviation : IAS


Plan


 DISCLOSURE: Dr Ryou disclosed that he is a founder of and consultant to, receives royalties from, and has equity in GI Windows and is a consultant to and received honoraria from Covidien and Medtronic. Dr Thompson is a founder of and consultant to, receives royalties from, and has equity in GI Windows; receives research support from and is a consultant to Olympus and Bard; is a consultant to Boston Scientific; is a consultant to, receives royalties from, and has stock in Beacon Endoscopic/Covidien. Dr Agoston disclosed no financial relationships relevant to this publication.


© 2016  American Society for Gastrointestinal Endoscopy. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 83 - N° 4

P. 821-825 - avril 2016 Retour au numéro
Article précédent Article précédent
  • EUS-guided portal pressure measurement using a digital pressure wire with real-time remote display: a novel, minimally invasive technique for direct measurement in an animal model
  • Allison R. Schulman, Christopher C. Thompson, Marvin Ryou
| Article suivant Article suivant
  • Weaving through the twists and turns of the fish bone case: demonstration of 2 different indications for endoscopic suturing in a single case of esophageal leak
  • Brian S. Lim, Armen Eskandari

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.