Are grown-up patients with congenital heart disease and mechanical valve using self-testing INR device? Experience feedback in a French population - 14/08/19

Doi : 10.1016/j.acvdsp.2019.06.032 
Olivia Domanski , Ali Houeijeh, Jean-Benoit Baudelet, Sophie Monsterleet, Isabelle Dufermont, François Godart
 CHRU de Lille, Cardiologie Pédiatrique et Congénitale, Lille, France 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Résumé

Background

The Coaguchek INRange® is a self-testing meter to measure the INR, that is reimbursed in France since August 2017 for patients with mechanical valve.

Methods

We evaluated the use of this anticoagulation method in a French population of GUCH (Grown-Up patients with Congenital Heart Disease) with mechanical valve.

Results

Since September 2018, 52 patients of 37±11 years old were asked to attend a training course of 2hours on anticoagulation and Coaguchek INRange® use, provided by specialized nurses, before getting home with the device. Patients had to attend a 3 months’ medical re-evaluation appointment. 29 (56%) patients had an aortic mechanical valve, 12 (23%) a mitral one, 8 (15%) a double aortic and mitral one, 2 (4%) a double aortic and pulmonary one and 1 (2%) a tricuspid one. 28 patients (54%) had a mechanical valve for10 years (group 1). In group 1, patients were older (41±10 years old vs. 34±10, P=0.01). Fluindione was the preferred oral anticoagulant (30 patients, 57%), and was more frequent in group 1 (18 patients, 64%). In group 1, 61% of patients usually managed themselves dosage adjustment whereas in the other group, 52% of patients referred to their doctor. Thirty-one patients (62%) had a higher target of INR than recommended in last European guidelines. Concerning follow-up, 26 patients (50%) did not attend the 3 months appointment and had to be rescheduled or contacted by phone. 8 patients (15%) did not use the device at 3 months: 5 for variation>15% compared to laboratory plasma technique and 3 for not trusting the new device. INR at 3 months was obtained in only 40 (77%) patients, and was in the attended target in 62% of cases.

Conclusion

GUCH patients with mechanical valves, especially when present for10 years, seem to validate Coaguchek, even though evaluation remains hard since a great proportion of them did not attend follow-up appointment, stick to their old INR target and did not use the device as often as recommended.

Le texte complet de cet article est disponible en PDF.

Plan


© 2019  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 11 - N° 4

P. e396-e397 - septembre 2019 Retour au numéro
Article précédent Article précédent
  • Electrical cardiometry and detection of left ventricular failure in right ventricular heart diseases
  • Angèle Boët, Julien Guihaire, Emmanuel Le Bret, Sébastien Hascoet, Gilles Jourdain, Virginie Lambert, Fabrice Antigny, Catherine Rucker-Martin
| Article suivant Article suivant
  • Single ventricle: Estimated cumulative irradiation during their life
  • Edouard Aries, Emeline Bigand, Fédoua El Louali, Philippe Aldebert, Florent Paoli, Caroline Ovaert

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.