S'abonner

Ultrasound-guided Morcellation During Difficult Holmium Laser Enucleation of the Prostate - 31/12/19

Doi : 10.1016/j.urology.2019.09.027 
David T. Tzou 1, 2, ⁎ , Ian S. Metzler 1, Catherine Tsai 3, Jeremy Goodman 1, David B. Bayne 1, Thomas Chi 1
1 Department of Urology, University of California San Francisco, San Francisco, CA 
2 Department of Urology, University of Arizona College of Medicine, Tucson, AZ 
3 Department of Surgery, University of California San Diego, La Jolla, CA 

⁎Address correspondence to: David T. Tzou, M.D., Department of Urology, University of Arizona College of Medicine, 1501 N. Campbell Ave, PO Box 245077, Tucson, AZ 85724.Division of UrologyDepartment of SurgeryUniversity of Arizona College of Medicine1501 N. Campbell Ave, PO Box 245077TucsonAZ85724

Abstract

Objective

To demonstrate how bladder ultrasound can be useful in completing morcellation during difficult Holmium Laser Enucleation of the Prostate (HoLEP). As HoLEP has emerged as a standard of care for the treatment of benign prostatic hyperplasia, multiple studies have reported the potentially catastrophic complication of bladder injury during morcellation. This video aims to assist any urologist performing HoLEP by providing step-by-step instruction for using ultrasound to complete morcellation safely.

Methods

Enucleation is performed using a 26-French continuous flow scope, off-set laser bridge with a laser stabilization catheter, and a 550 µm holmium laser fiber. Once the median and lateral lobes have been enucleated, the outer sheath is removed and the nephroscope is inserted to facilitate morcellation. Under dual inflow irrigation, the Piranha morcellator (Richard Wolf, Knittlingen, Germany) is introduced and set to the manufacturer's recommended settings of 1500 rpm. A 3.5-MHz convex abdominal ultrasound transducer (Hitachi Prosound Alpha 7; Hitachi Aloka Medical America, Wallingford, CT) under B-mode is used to visualize the bladder, predominantly in the sagittal orientation. Morcellation proceeds under simultaneous ultrasound and direct cystoscopic guidance.

Results

The distended bladder is visualized concurrently with the ultrasound and via the nephroscope as the Piranha engages the adenoma and begins morcellation. Once the adenoma is engaged, the operator then drops their hands to place the morcellator in the center of the bladder. Ultrasound provides real-time feedback as to the location of the morcellator in relation to the adenoma and bladder.

Conclusion

This video highlights the use of intraoperative bladder ultrasound as a visual aid to assist during the morcellation portion of HoLEP. This proof of concept demonstrates that ultrasound can be an additional tool to utilize during difficult cases when cystoscopic visualization during morcellation is limited.

Le texte complet de cet article est disponible en PDF.

Plan


 Funding: National Institute of Health (NIH), R21-DK-109433.
 Declarations of Interest: We wish to confirm that there are no known conflicts of interest associated with this publication and there has been no significant financial support for this work that could have influenced its outcome.
 Financial Disclosures: David T Tzou: Consultant for Boston Scientific Corporation; Ian S Metzler: None; Catherine Tsai: none; Jeremy Goodman: None; David B Bayne: None; Thomas Chi: Consultant for Boston Scientific Corporation, Consultant for Auris Robotics.


© 2019  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 135

P. 171-172 - janvier 2020 Retour au numéro
Article précédent Article précédent
  • Presentation and Management Patterns of Lower Urinary Tract Symptoms in Adults Due to Rare Inherited Neuromuscular Diseases
  • Joshua D. Roth, Joseph J. Pariser, Thomas E. Stout, Rosalia Misseri, Sean P. Elliott
| Article suivant Article suivant
  • Marks Sheldon H.F. Vasectomy Reversal: Manual of Vasovasostomy and Vasoepididymostomy. Springer International PublishingBasel, Switzerland (2019)
  • Manish Narasimman, Ranjith Ramasamy

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.