S'abonner

Impact of EUS-guided microforceps biopsy sampling and needle-based confocal laser endomicroscopy on the diagnostic yield and clinical management of pancreatic cystic lesions - 20/04/20

Doi : 10.1016/j.gie.2019.12.022 
Antonio R. Cheesman, MD 1, Hongfa Zhu, MD, PhD 2, Xiaoyan Liao, MD, PhD 2, Arnold H. Szporn, MD 2, Nikhil A. Kumta, MD, MS 1, Satish Nagula, MD 1, Christopher J. DiMaio, MD 1,
1 Division of Gastroenterology, Icahn School of Medicine at Mount Sinai, New York, New York, USA 
2 Department of Pathology, Icahn School of Medicine at Mount Sinai, New York, New York, USA 

Reprint requests: Christopher J. DiMaio, MD, FASGE, Dr Henry D. Janowitz Division of Gastroenterology, Icahn School of Medicine at Mount Sinai, One Gustave L. Levy Place, Box 1069, New York, NY 10029.Dr Henry D. Janowitz Division of GastroenterologyIcahn School of Medicine at Mount SinaiOne Gustave L. Levy PlaceBox 1069New YorkNY10029

Abstract

Background and Aims

EUS-guided microforceps biopsy sampling (MFB) and needle-based confocal laser endomicroscopy (nCLE) are emerging diagnostic tools for pancreatic cystic lesions (PCLs). There is a paucity of data regarding their performance and impact. The aim of this study was to compare diagnostic outcomes and changes in clinical management resulting from MFB and nCLE use in PCLs.

Methods

This was a single-center retrospective study of patients with PCLs who underwent combined EUS-guided FNA, MFB, and nCLE. Primary outcomes included diagnostic yield (specific PCL type) and change in clinical management for each modality compared with the current “composite standard” (CS) obtained by combining clinical, morphologic, cyst fluid cytology, and chemical analysis.

Results

Forty-four cysts were studied in 44 patients. Technical success was 100% for EUS-FNA, 88.6% for MFB, and 97.7% for nCLE. Of 44 procedures, there was 1 adverse event (2.3%, an infected pseudocyst). Diagnostic yield for each individual modality was 34.1% for CS, 75.0% for MFB (P < .05 vs CS), and 84.1% for nCLE (P < .05 vs CS). Diagnostic yield for combined tests was 79.5% for CS/MFB, 88.6% for CS/nCLE, and 93.2% for CS/MFB/nCLE (P = not significant). Compared with the CS, the use of MFB, nCLE, and their combination led to overall change in clinical management in 38.6%, 43.2%, and 52.3% of cases, respectively. MFB and nCLE led to an overall increase in discontinuation of surveillance (MFB, 34.1% [P < .05]; nCLE, 31.8% [P < .05]), led by a reduction in the indication for follow-up radiologic or endoscopic studies (MFB, 34.1% [P < .05]; nCLE, 38.6% [P < .05]). Based on MFB and nCLE, 2 of 28 (7.1%) and 3 of 28 (10.7%) patients who would have undergone further surveillance were referred for surgery.

Conclusions

In the evaluation of PCLs, the use of combined EUS-guided FNA, MFB, and nCLE is safe. MFB and nCLE led to significant improvements in specific PCL diagnosis, which in turn has major impacts in clinical management.

Le texte complet de cet article est disponible en PDF.

Abbreviations : CEA, CS, MFB, nCLE, PD, PCL


Plan


 DISCLOSURE: The following authors disclosed financial relationships: A. R. Cheesman: Expenses from Olympus. N. A. Kumta: Consultant for Boston Scientific, Olympus, Apollo Endosurgery, and Gyrus Acmi, Inc; speaker for Boston Scientific and Apollo Endosurgery; expenses from Boston Scientific, Olympus, EndoGastric Solutions, and Gyrus Acmi, Inc. C. J. DiMaio: Consultant and speaker for Boston Scientific and Medtronic; expenses from Boston Scientific, Cook Medical, EndoGastric Solutions, and US Endoscopy. All other authors disclosed no financial relationships.
 See CME section; p. 1187.
 If you would like to chat with an author of this article, you may contact Dr DiMaio at Christopher.DiMaio@mountsinai.org.


© 2020  American Society for Gastrointestinal Endoscopy. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 91 - N° 5

P. 1095-1104 - mai 2020 Retour au numéro
Article précédent Article précédent
  • Treatment of postoperative pancreatic fluid collections
  • Gregory A. Coté
| Article suivant Article suivant
  • Digital single-operator peroral cholangioscopy-guided biopsy sampling versus ERCP-guided brushing for indeterminate biliary strictures: a prospective, randomized, multicenter trial (with video)
  • Christian Gerges, Torsten Beyna, Raymond S.Y. Tang, Farzan Bahin, James Y.W. Lau, Erwin van Geenen, Horst Neuhaus, Duvvur Nageshwar Reddy, Mohan Ramchandani

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.