S'abonner

Can high-functioning amputees with state-of-the-art prosthetics walk normally? A kinematic and dynamic study of 40 individuals - 23/05/20

Can high-functioning amputees with state-of-the-art prosthetics walk normally? A kinematic and dynamic study of 40 individuals

Doi : 10.1016/j.rehab.2020.04.007 
Hannah L Jarvis 1, 2, , Neil D Reeves 1, Martin Twiste 2, 3, Rhodri D Phillip 4, John Etherington 4, Alexander N Bennett 4, 5, 6
1 Research Centre for Musculoskeletal Science and Sports Medicine, Department of Life Sciences, Faculty of Science and Engineering, Manchester Metropolitan University, Manchester, UK 
2 School of Health Sciences, University of Salford, Salford, UK 
3 United National Institute for Prosthetics & Orthotics Development (UNIPOD), University of Salford, Salford, UK 
4 Academic Department of Military Rehabilitation, Defence Medical Rehabilitation Centre, Headley Court, Epsom, Surrey, UK 
5 Leeds Institute of Rheumatic and Musculoskeletal Medicine, University of Leeds, Leeds, UK 
6 National Heart and Lung Institute, Faculty of Medicine, Imperial College London, London, UK 

Corresponding author.
Sous presse. Manuscrit accepté. Disponible en ligne depuis le Saturday 23 May 2020
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Abstract

Background. Previous work has highlighted the highly functional post-rehabilitation level of military individuals who sustained traumatic amputation. Understanding how these individuals walk with their prosthesis could be key to setting a precedent for what is realistically possible in the rehabilitation of individuals with amputations.

Objective. The aim of this paper is to answer how “normal” should the gait of an individual with an amputation(s) be and can we aspire to mimic able-bodied gait with the most advanced prosthetics in highly functioning individuals?

Methods. This was a cross-sectional study comparing the gait of severely injured and highly functional UK trans-tibial (n=10), trans-femoral (n=10) and bilateral trans-femoral (n=10) military amputees after completion of their rehabilitation programme to that of able-bodied controls (n=10). Joint kinematics and kinetics of the pelvis, hip, knee and ankle were measured with 3-D gait analysis during 5min of walking on level ground at a self-selected speed. Peak angle, moment or range of motion of intact and prosthetic limbs were compared to control values.

Results. Joint kinematics of unilateral trans-tibial amputees was similar to that of controls. Individuals with a trans-femoral amputation walked with a more anterior tilted pelvis (p=0.006), with reduced range of pelvic obliquity (p=0.0023) and ankle plantarflexion (p<0.001) than controls. Across all amputee groups, hip joint moments and power were greater and knee and ankle joint moments were less than for controls.

Conclusions. This is the first study to provide a comprehensive description of gait patterns of unilateral trans-tibial, trans-femoral and bilateral trans-femoral amputees as compared with healthy able-bodied individuals. The groups differed in joint kinematics and kinetics, but these can be expected in part because of limitations in prosthesis and socket designs. The results from this study could be considered benchmark data for healthcare professionals to compare gait patterns of other individuals with amputation who experienced similar injuries and rehabilitation services.

Le texte complet de cet article est disponible en PDF.

Keywords : Amputation, trans-tibial, trans-femoral, kinematics, kinetics, gait, biomechanics



© 2020  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.