S'abonner

Étude expérimentale de la microtomographie X dans l’évaluation de la fusion osseuse - 18/04/08

Doi : 10.1016/S0035-1040(06)75910-4 
H. Pascal-Moussellard 1, , B. Brunet-Imbault 2, E. Aguado 3, P. Pilet 4, S. Delplace 4, C.-L. Benhamou 2, G. Daculsi 4
1 Service d’Orthopédie, Pavillon Gaston-Cordier, CHU Pitié-Salpétrière, 47, boulevard de l’Hôpital, 75013 Paris 
2 Institut de prévention et de recherche sur l’ostéoporose (INSERM ERIT-M 0101), Orléans 
3 École Nationale Vétérinaire de Nantes 
4 UMR S, Centre de recherche en ingénierie ostéo-articulaire et dentaire, Nantes 

Correspondance: H. Pascal-Moussellard à l’adresse ci-dessus.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 8
Iconographies 0
Vidéos 0
Autres 0

Résumé

Affirmer avec certitude la fusion d’une arthrodèse reste difficile malgré les progrès des techniques d’imagerie. Le microscanner est une technique d’imagerie qui permet une analyse à la fois qualitative et quantitative de la micro-architecture osseuse.

L’objectif de cette étude était d’évaluer cette technique en l’appliquant à l’arthrodèse cervicale avec cage inter-somatique sur un modèle animal et de valider les résultats par une analyse histologique et en microscopie électronique à balayage.

Huit chèvres ont été opérées d’une discectomie au niveau C3-C4 et réparties en deux groupes. Le groupe 1 (3 animaux) a été implanté avec des cages en PEEK sans greffon osseux. Le groupe 2 (5 chèvres) a été implanté avec la même cage remplie d’os autologue iliaque. Après euthanasie, au 6e mois, les niveaux instrumentés ont été analysés au microscanner, puis sur coupe histologique et en microscopie électronique à balayage (MEB).

Les 3 animaux implantés avec une cage vide (groupe 1) ont développé une pseudarthrose, tandis qu’un seul animal présentait une pseudarthrose dans le groupe 2. Les analyses histologique et MEB ont confirmé le diagnostic fait par microscanner. Le microscanner a, en outre, permis l’analyse en 3 dimensions de l’échantillon et l’étude de l’architecture trabéculaire du greffon inter-somatique.

Le microscanner permet une analyse micrométrique d’un échantillon. Il représente la seule technique d’analyse en 3 dimensions (des coupes sont possible dans les trois plans de l’espace et la reconstruction 3D visualise l’ensemble de l’échantillon) à la fois qualitative et quantitative. L’analyse de la micro-architecture trabéculaire est un progrès majeur dans l’évaluation de la valeur mécanique d’une arthrodèse. Il s’agit de la seule technique non destructrice pour l’échantillon, qui reste utilisable pour d’autres tests en particulier biomécanique.

Le microscanner représente une avancée technique pour l’analyse de la fusion osseuse. Les applications futures de cette technique quantitative seront vraisemblablement nombreuses (suivi d’une arthrodèse, évaluation de la qualité mécanique d’une greffe…). Son adaptation in vivo sera vraisemblablement rapide.

Le texte complet de cet article est disponible en PDF.

Abstract

Purpose of the study

Certain confirmation of bone fusion remains difficult to obtain after arthrodesis despite progress in imaging techniques. Microscanning enables both qualitative and quantitative analysis of the bone microarchitecture. The purpose of this study was to evaluate this technique using a cervical arthrodesis with an intersomatic cage on an animal model and to validate results with histological analysis and electron scan microscopy (SEM).

Material and methods

C3-C4 discectomy was performed in 8 goats divided into two groups. In group 1 (3 animals), PEEK cages were inserted without bone graft. In group 2 (5 goats) the same cage was inserted and filled with an autologous iliac graft. The animals were sacrificed at six months. The instrumented levels were analyzed with a microscan. Histological slides were obtained and SEM performed.

Results

Nonunion was observed in the three animals with an empty cage (group 1) while only one animal in group 2 presented nonunion. Histology and SEM confirmed the diagnosis established with the microscan which also enabled a 3D analysis of the sample and study of the trabecular architecture of the intersomatic graft.

Discussion

The microscan enabled a micrometric analysis of the sample. This is the only technique enabling 3D analysis (slices can be obtained in the three planes for 3D reconstruction) for both qualitative and quantitative assessment. Analysis of the trabecular microstructure constitutes a major progress in evaluating the mechanical value of the fusion. The sample is not destroyed and can be studied further with other biomechanical techniques.

Conclusion

Microscanning is an important technical advancement for the analysis of bone fusion. Future applications will undoubtedly be numerous (follow-up after arthrodsis, analysis of the mechanical quality of a graft). In vivo applications will probably be adapted soon.

Le texte complet de cet article est disponible en PDF.

Mots clés : Microtomographie, fusion osseuse

Key words : Microscan, bone fusion


Plan

Plan indisponible

© 2006  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 92 - N° 6

P. 535-542 - octobre 2006 Retour au numéro
Article suivant Article suivant
  • Arthroplastie inversée de Grammont pour fracture récente de l’humérus proximal chez la personne âgée avec un recul de 5 à 12 ans
  • J.-F. Cazeneuve, D.-J. Cristofari

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.