S'abonner

Predicting Visual Fields From Optical Coherence Tomography via an Ensemble of Deep Representation Learners - 23/05/22

Doi : 10.1016/j.ajo.2021.12.020 
Georgios Lazaridis a, b, , Giovanni Montesano a, c, Saman Sadeghi Afgeh d, Jibran Mohamed-Noriega a, e, Sebastien Ourselin f, Marco Lorenzi g, David F. Garway-Heath a
a From the NIHR Biomedical Research Centre at Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology (G.L., G.M., J.M.-N., D.F.G.-H.), London, United Kingdom 
b Centre for Medical Image Computing, University College London (G.L.), London, United Kingdom 
c Optometry and Visual Sciences, City, University of London, London, United Kingdom 
d Data Science Institute, City University (S.S.A.), London, United Kingdom 
e Departamento de Oftalmología, Hospital Universitario (J.M.-N.), UANL, México 
f School of Biomedical Engineering and Imaging Sciences, King's College London (S.O.), London, United Kingdom and 
g Université Côte d'Azur, Inria Sophia Antipolis, Epione Research Project (M.L.), Valbonne, France 

Inquiries to Georgios Lazaridis, Centre for Medical Image Computing (CMIC), University College London, 90 High Holborn, Floor 1, London, WC1V 6LJ.Centre for Medical Image Computing (CMIC)University College London90 High Holborn, Floor 1LondonWC1V 6LJ

Résumé

PURPOSE

To develop and validate a deep learning method of predicting visual function from spectral domain optical coherence tomography (SD-OCT)–derived retinal nerve fiber layer thickness (RNFLT) measurements and corresponding SD-OCT images.

DESIGN

Development and evaluation of diagnostic technology.

METHODS

Two deep learning ensemble models to predict pointwise VF sensitivity from SD-OCT images (model 1: RNFLT profile only; model 2: RNFLT profile plus SD-OCT image) and 2 reference models were developed. All models were tested in an independent test-retest data set comprising 2181 SD-OCT/VF pairs; the median of ∼10 VFs per eye was taken as the best available estimate (BAE) of the true VF. The performance of single VFs predicting the BAE VF was also evaluated. The training data set comprised 954 eyes of 220 healthy and 332 glaucomatous participants, and the test data set, 144 eyes of 72 glaucomatous participants. The main outcome measures included the pointwise prediction mean error (ME), mean absolute error (MAE), and correlation of predictions with the BAE VF sensitivity.

RESULTS

The median mean deviation was –4.17 dB (–14.22 to 0.88). Model 2 had excellent accuracy (ME 0.5 dB, SD 0.8) and overall performance (MAE 2.3 dB, SD 3.1), and significantly (paired t test) outperformed the other methods. For single VFs predicting the BAE VF, the pointwise MAE was 1.5 dB (SD 0.7). The association between SD-OCT and single VF predictions of the BAE pointwise VF sensitivities was R2 = 0.78 and R2 = 0.88, respectively.

CONCLUSIONS

Our method outperformed standard statistical and deep learning approaches. Predictions of BAEs from OCT images approached the accuracy of single real VF estimates of the BAE.

Le texte complet de cet article est disponible en PDF.

Plan


 Supplemental Material available at AJO.com.


© 2022  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 238

P. 52-65 - juin 2022 Retour au numéro
Article précédent Article précédent
  • Corneal Biometric Features and Their Association With Axial Length in High Myopia
  • Guangming Jin, Zhenzhen Liu, Lanhua Wang, Yi Zhu, Lixia Luo, Yizhi Liu
| Article suivant Article suivant
  • Intraocular Inflammation in Eyes Operated for Late In-the-bag intraOcular lens dislocatioN (LION): A Randomized Clinical Trial
  • HELLE MEDIN, MARIUS DALBY, INGEBORG SLØRDAHL HJORT KURE, MIA KARABEG, LIV DROLSUM, OLAV KRISTIANSLUND

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.