S'abonner

Multichamber Strain Characterization Is a Robust Prognosticator for Both Bicuspid and Tricuspid Aortic Stenosis - 02/09/22

Doi : 10.1016/j.echo.2022.05.010 
Zi Ye, MD, PhD a, Li-Tan Yang, MD b, Jose R. Medina-Inojosa, MD, MS a, c, Christopher G. Scott, MS d, Ratnasari Padang, MBBS, PhD a, S. Allen Luis, MBBS, PhD a, Vuyisile T. Nkomo, MD, MPH a, Maurice Enriquez-Sarano, MD a, Hector I. Michelena, MD a,
a Department of Cardiovascular Medicine, Mayo Clinic, Rochester, Minnesota 
b Cardiovascular Center and Division of Cardiology, Department of Internal Medicine, National Taiwan University Hospital, Taipei, Taiwan 
c Division of Epidemiology, Department of Quantitative Health Sciences, Mayo Clinic, Rochester, Minnesota 
d Division of Biomedical Statistics and Informatics, Mayo Clinic, Rochester, Minnesota 

Reprint requests: Hector I. Michelena, MD, Mayo Clinic, 200 First Street SW, Rochester, MN 55905.Mayo Clinic200 First Street SWRochesterMN55905

Abstract

Background

Cardiac damage (CD) staging is associated with worse survival in aortic stenosis (AS). However, patients with bicuspid aortic valve (BAV) are less likely to develop CD than those with tricuspid aortic valve AS (TAV-AS). The aim of this study was to assess the prognostic value of multichamber strain (MCS) characterization, a sensitive measurement of subclinical CD, in patients with BAV- and TAV-AS.

Methods

Offline two-dimensional echocardiographic strain analysis was performed in 209 consecutive patients with BAV and 369 patients with TAV with more than moderate AS (mean gradient, 47 ± 12 vs 47 ± 14 mm Hg, respectively; >90% severe AS), retrospectively identified from the echocardiography database. The extent of abnormal cardiac mechanics was characterized by the number of chambers with impaired longitudinal strain (left ventricle, left atrium, and right ventricle) as preserved or single-chamber, paired-chamber, or triple-chamber impaired strain. Cutoffs of strain parameters to define impaired versus preserved chamber function were 15% for the left ventricle, 24% for the left atrium, and 25% for the right ventricular free wall. CD was staged using a panel of comprehensive echocardiographic parameters. The primary outcome was all-cause death.

Results

MCS (per chamber increase) modestly correlated with CD staging (per stage increase) in both groups (BAV, r = 0.36; TAV, r = 0.43). After a median follow-up period of 4.9 years (interquartile range, 2.2-4.6 years), 262 patients died (5-year survival 86.8 ± 2.4% [BAV-AS] vs 49.6 ± 2.7% [TAV-AS], P < .001). In multivariable analysis, MCS was strongly associated with all-cause death in BAV-AS and TAV-AS, separately, and independent of CD staging (P < .001 for both). MCS provided incremental prognostic value to CD staging in both BAV-AS and TAV-AS (P for χ2 change < .001 for both) and improved risk classification of CD staging in TAV AS (continuous net reclassification index = 0.24, P = .02).

Conclusion

MCS characterization is a robust prognosticator in patients with greater than moderate AS and provides incremental prognostic value to CD staging in both BAV-AS and TAV-AS. Therefore, MCS characterization could represent an alternative or additive method to CD staging.

Le texte complet de cet article est disponible en PDF.

Highlights

Despite similar AS severity, BAV AS patients exhibit better CD stage than TAV AS.
In both BAV and TAV AS, strain detects abnormalities not detected by CD staging.
MCS characterization is a robust prognosticator in BAV and TAV AS.
MCS characterization improves the prognostic value of CD staging.
With MCS impairment, post-AVR survival may be compromised.

Le texte complet de cet article est disponible en PDF.

Keywords : Aortic stenosis, Bicuspid aortic valve, Strain

Abbreviations : AS, AV, AVA, AVR, BAV, CD, GLS, IQR, LA, LASr, LV, MCS, MG, RV, RVFWLS, TAV


Plan


 Conflicts of Interest: None.


© 2022  American Society of Echocardiography. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 35 - N° 9

P. 956-965 - septembre 2022 Retour au numéro
Article précédent Article précédent
  • Incremental Prognostic Value of Left Ventricular Global Longitudinal Strain in Patients with Preserved Ejection Fraction Undergoing Transcatheter Aortic Valve Implantation
  • Sun-Hack Lee, Jin Kyung Oh, Seung-Ah Lee, Do-Yoon Kang, Sahmin Lee, Ho Jin Kim, Jung-Min Ahn, Joon Bum Kim, Duk-Woo Park, Jong-Min Song, Suk Jung Choo, Duk-Hyun Kang, Jae-Kwan Song, Seung-Jung Park, Jung Hyun Choi, Dae-Hee Kim
| Article suivant Article suivant
  • Prognostic Value of the MAGGIC Score, H2FPEF Score, and HFA-PEFF Algorithm in Patients with Exertional Dyspnea and the Incremental Value of Exercise Echocardiography
  • Monika Przewlocka-Kosmala, Javed Butler, Erwan Donal, Piotr Ponikowski, Wojciech Kosmala

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.