S'abonner

Microbiological surveillance post-reprocessing of flexible endoscopes used in digestive endoscopy: a national study - 12/01/23

Doi : 10.1016/j.jhin.2022.09.024 
B. Casini a, A.M. Spagnolo b, c, , M. Sartini b, c, , B. Tuvo a, M. Scarpaci a, M. Barchitta d, A. Pan e, A. Agodi d, M.L. Cristina b, c

on behalf of the Study Group

  Full details of the Study Group Collaborators provided in Appendix.
L. Baroncelli, P. Castiglia, M. De Giusti, M.M. Distefano, A.M. Longhitano, P. Laganà, B. Mentore, F. Canale, F. Mantero, M. Opezzi, E. Marciano, L. Zurlo, A. Segata, I. Torre, D. Vay, E. Vecchi, S. Vincenti

a Department of Translational Research, New Technologies in Medicine and Surgery, University of Pisa, Pisa, Italy 
b Department of Health Sciences, University of Genova, Genova, Italy 
c Operating Unit Hospital Hygiene, Galliera Hospital, Genoa, Italy 
d Department of Medical, Surgical and Advanced Technology Sciences “G.F. Ingrassia”, University of Catania, Catania, Italy 
e Operating Unit of Infectious Diseases, ASST Cremona, Cremona, Italy 

Corresponding authors. Address: Department of Health Sciences, University of Genova, Via Pastore 1, Genova 16132, Italy.Department of Health SciencesUniversity of GenovaVia Pastore 1Genova16132Italy

Summary

Introduction

Microbiological surveillance of endoscopes is a safety measure for verifying the quality of reprocessing procedures and identifying contaminated devices, but duodenoscope-related outbreaks are still reported.

Aim

To assess the effectiveness of duodenoscope reprocessing procedures in Italy.

Methods

Between December 2019 and April 2020, data obtained from microbiological surveillance post-reprocessing in 15 Italian endoscopy units were collected. Sampling was carried out after reprocessing or during storage in a cabinet. In keeping with international guidelines and the Italian position paper, the micro-organisms were classified as high-concern organisms (HCOs) and low-concern organisms (LCOs).

Findings

In total, 144 samples were collected from 51 duodenoscopes. Of these, 36.81% were contaminated: 22.92% were contaminated with HCOs and 13.89% were contaminated with LCOs [2.08% with an LCO load of 11–100 colony-forming units (CFU)/device and 0.69% with an LCO load of >100 CFU/device]. The contamination rate was 27.5% in samples collected after reprocessing, 40% in samples collected during storage in a cabinet that was compliant with EN 16442:2015 (C-I), and 100% in samples collected during storage in a cabinet that was not compliant with EN 16442:2015 (NC-I). The respective HCO rates were 15.00%, 27.27% and 66.67%. Correlation between LCO contamination and storage time was demonstrated (Spearman's rho=0.3701; P=0.0026). The Olympus duodenoscope TJFQ180V demonstrated the lowest rate of contamination (29.82%), although the contamination rate was 100% for duodenoscopes stored in an NC-I cabinet.

Conclusion

Microbiological surveillance, along with strict adherence to reprocessing protocols, may help to detect endoscope contamination at an early stage, and reduce the risk of duodenoscope-associated infections.

Le texte complet de cet article est disponible en PDF.

Keywords : Duodenoscopes, Endoscope reprocessing, Microbiological surveillance, Survey


Plan


© 2022  The Authors. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 131

P. 139-147 - janvier 2023 Retour au numéro
Article précédent Article précédent
  • Epidemiology of healthcare-associated infections and mechanisms of antimicrobial resistance of responsible pathogens in Ukraine: a multicentre study
  • A. Salmanov, D. Shchehlov, O. Svyrydiuk, I. Bortnik, M. Mamonova, S. Korniyenko, V. Rud, V. Artyomenko, M. Gudym, R. Maliarchuk, T. Bondar
| Article suivant Article suivant
  • Eye-tracking to observe compliance with hand hygiene in the intensive care unit: a randomized feasibility study
  • R. Valek, P.D. Wendel-Garcia, R.A. Schuepbach, P.K. Buehler, D.A. Hofmaenner

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.