S'abonner

Étude anatomique d’un embryon humain issu d’une grossesse extra-utérine par micro-tomodensitométrie - 04/12/25

Anatomical study of an early human embryo from an ectopic pregnancy by micro-computed tomography

Doi : 10.1016/j.annpat.2025.11.002 
Romain Martineau a, , Maïda Cardoso b , Audrey Lamouroux c, d, e
a University of Medicine Montpellier-Nîmes, 641, avenue du Doyen Gaston-Giraud, 34090 Montpellier, France 
b UMR 5221, University Montpellier, CNRS, 34095 Montpellier, France 
c Charles Coulomb Laboratory, UMR 5221 CNRS-UM, BNIF User Facility Imaging, University of Montpellier, CNRS, Montpellier, France 
d ICAR Research Team, LIRMM, University of Montpellier, CNRS, Montpellier, France 
e Obstetrical Gynaecology Department, Nîmes University Hospital, University of Montpellier, Nîmes, France 

Auteur correspondant.
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Thursday 04 December 2025

Résumé

Introduction

La micro-tomodensitométrie (micro-CT) offre une imagerie tridimensionnelle à haute résolution des structures embryonnaires, surmontant les limites de l’autopsie standard en cas de perte précoce de grossesse.

Objectif

Évaluer la faisabilité et la pertinence de l’imagerie par micro-CT dans l’étude anatomique d’un embryon humain issu d’une grossesse extra-utérine.

Matériels et méthodes

Après une salpingectomie réalisée par cœlioscopie, un embryon bien conservé de 8 mm a été prélevé, fixé au formaldéhyde et immergé dans un bain de contraste à base d’iode avant d’être imagé par micro-CT avec une résolution isotropique de 12 μm.

Résultats

L’embryon, classé au stade Carnegie 15, a été examiné en détail. La micro-CT a permis une visualisation 3D non destructive de multiples structures internes, incluant les poumons, le cœur, le foie, la rate, le tube neural et les structures craniofaciales.

Discussion et conclusion

La micro-CT est un outil prometteur pour l’étude du développement humain précoce à partir de spécimens issus de grossesses extra-utérines. Elle permet une analyse morphologique détaillée aux stades très précoces, améliore la compréhension de l’embryogenèse et peut compléter les examens post-mortem de routine.

Le texte complet de cet article est disponible en PDF.

Summary

Background

Micro-computed tomography (micro-CT) offers high-resolution, three-dimensional imaging of embryonic structures, overcoming limitations of standard autopsy in early loss of pregnancy.

Objective

To assess the feasibility and relevance of micro-CT imaging in the anatomical study of a human embryo obtained from ectopic pregnancy.

Materials and methods

Following laparoscopic salpingectomy, a well-preserved 8 mm embryo was extracted, fixed in formaldehyde, and stained with iodine-based contrast before being imaged using micro-CT at 12 μm isotropic resolution.

Results

The embryo, classified as Carnegie stage 15, was examined in detail. Micro-CT allowed non-destructive 3D visualization of multiple internal structures, including lungs, heart, liver, spleen, neural tube, and craniofacial features.

Discussion and conclusion

Micro-CT is a promising tool for studying early human development using specimens from ectopic pregnancies. It enables detailed morphological analysis at very early stages, enhances understanding of embryogenesis, and may complement routine postmortem examinations.

Le texte complet de cet article est disponible en PDF.

Mots clés : Grossesse extra-utérine, Développement embryonnaire, Micro-tomodensitométrie, Micro-CT, Micro-imagerie

Keywords : Ectopic pregnancy, Embryo development, Micro-computed tomography, Micro-CT, Micro-imaging


Plan


© 2025  The Authors. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.