S'abonner

Fixation arthroscopique coracoclaviculaire avec dispositif à double bouton pour fractures aiguës instables du quart externe de la clavicule : une étude rétrospective - 21/02/26

Arthroscopic coracoclavicular fixation with double button device for acute unstable distal clavicle fracture: A retrospective review

Doi : 10.1016/j.rcot.2026.01.008 
Olivier Freaud 1, François Montseny 2, Sarah Amar 4, Alain Sautet 1, 3, Adeline Cambon-Binder 1, 3, Claire Bastard 1, , 3
1 Sorbonne université, hôpital Saint-Antoine, service de chirurgie de la main, service d’orthopédie et de traumatologique, 184, rue du Faubourg-Saint-Antoine, 75012 Paris, France 
2 Université Paris XIII, hôpital Avicenne, service de chirurgie de la main, service d’orthopédie et de traumatologie, 125, rue de Stalingrad, 93000 Bobigny, France 
3 Sorbonne université, Paris, France 
4 Hôpital d’instruction des Armées Bégin, service de chirurgie orthopédique et traumatologique, 69, avenue de Paris, 94160 Saint-Mandé, France 

Claire Bastard, Sorbonne université, hôpital Saint-Antoine, service de chirurgie de la main, service d’orthopédie et de traumatologique, 184, rue du Faubourg-Saint-Antoine, 75012 Paris, France. Sorbonne université, hôpital Saint-Antoine, service de chirurgie de la main, service d’orthopédie et de traumatologique 184, rue du Faubourg-Saint-Antoine Paris 75012 France
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Saturday 21 February 2026

Résumé

Introduction

Les fractures du quart latéral de la clavicule représentent le deuxième type le plus fréquent de fracture de la clavicule, après les fractures du tiers moyen. Leur prise en charge reste controversée, en particulier pour les fractures instables de type IIA, IIB et V de la classification de Neer. La fixation coracoclaviculaire arthroscopique à l’aide d’un double endo-bouton constitue une option chirurgicale moderne, potentiellement moins invasive.

Hypothèse

Nous avons émis l’hypothèse que la fixation coracoclaviculaire arthroscopique par double endo-bouton permet d’obtenir un taux de consolidation 80 % avec un faible taux de complications, y compris dans une série comportant une proportion importante de fractures de type V.

Matériels et méthodes

Nous avons mené une étude rétrospective monocentrique incluant 41 patients traités entre mars 2017 et juillet 2022 par fixation coracoclaviculaire arthroscopique à double endo-bouton pour une fracture instable du quart latéral de la clavicule (types IIA, IIB, V de Neer). L’évaluation comprenait un critère principal qui était le taux de consolidation, et des critères secondaires étant les scores fonctionnels (Constant, QuickDASH et SSV), les complications et la reprise des activités professionnelles et sportives.

Résultats

Quarante et un patients ont été inclus. Le suivi moyen était de 35,7 mois. Trente-sept patients (90 %) avaient consolidé à six mois. Le groupe de patients ayant une pseudarthrose au dernier suivi avait un âge significativement plus élevé (51,2 vs 34,4 ans ; p = 0,015), un indice de masse corporelle plus élevé (26 vs 22,6 kg/m 2  ; p = 0,037), et un délai de prise en charge plus élevé (8,5 vs 4,4 jours ; p = 0,015) comparé aux patients ayant consolidé. Au dernier suivi, le score de Constant moyen était de 90,8 ± 11,6, le QuickDASH moyen de 2,6 ± 6 et le SSV moyen de 91,5 ± 9. Tous les patients ont pu reprendre leurs activités sportives et professionnelles au même niveau qu’avant le traumatisme. Le délai moyen de reprise du travail était de 1,6 ± 1,1 mois. Le délai moyen de reprise des activités sportives était de 3,7 ± 2,3 mois. Il n’y a pas eu de complication septique. Aucune révision chirurgicale n’a été nécessaire, les pseudarthroses ayant été traitées fonctionnellement.

Conclusion

La fixation coracoclaviculaire arthroscopique par double endo-bouton est une technique fiable, avec un taux de consolidation comparable ou supérieur à ceux rapportés dans la littérature pour les fractures instables du quart latéral de la clavicule. Un âge avancé, un IMC élevé et un délai de prise en charge prolongé sont significativement associés à un risque accru de pseudarthrose.

Niveau de preuve

IV ; étude rétrospective.

Le texte complet de cet article est disponible en PDF.

Summary

Background

Distal clavicle fractures are the second most common type of clavicle fracture after midshaft fractures. Their management remains controversial, particularly for unstable fractures of types IIA, IIB, and V according to the Neer classification. Arthroscopic coracoclavicular fixation using a double button device represents a modern surgical option that is potentially less invasive.

Hypothesis

We hypothesized that arthroscopic coracoclavicular fixation with a double button device would achieve a union rate 80% with a low complication rate, including in a series with a high proportion of type V fractures.

Methods

We conducted a retrospective single-center study including 41 patients treated between March 2017 and July 2022 with arthroscopic coracoclavicular fixation using a double button device for unstable distal clavicle fractures (Neer types IIA, IIB, and V). The primary outcome was the union rate. Secondary outcomes included functional scores (Constant, QuickDASH, and SSV), complications, and return to work and sports.

Results

Forty-one patients were included, with a mean follow-up of 35.7 months. Thirty-seven patients (90%) achieved union at six months. Patients with nonunion at final follow-up were significantly older (51.2 vs. 34.4 years; P = 0.015), had a higher body mass index (26.0 vs. 22.6 kg/m 2 ; P = 0.037), and a longer time to surgery (8.5 vs. 4.4 days; P = 0.015) compared with patients who consolidated. At last follow-up, the mean Constant score was 90.8 ± 11.6, the mean QuickDASH was 2.6 ± 6, and the mean SSV was 91.5 ± 9. All patients were able to return to their pre-injury work and sports activities. The mean time to return to work was 1.6 ± 1.1 months, and the mean time to return to sports was 3.7 ± 2.3 months. No septic complications occurred. No surgical revision was required, as nonunions were managed conservatively.

Discussion

Arthroscopic coracoclavicular fixation with a double button device is a reliable technique, providing union and functional outcomes comparable or superior to those reported in the literature for unstable distal clavicle fractures. Older age, higher BMI, and delayed surgery were significantly associated with an increased risk of nonunion.

Level of evidence

IV; therapeutic case series.

Le texte complet de cet article est disponible en PDF.

Mots clés : Fracture distale de la clavicule, Chirurgie, Arthroscopie, Fixation coracoclaviculaire, Pseudarthrose

Keywords : Distal clavicle fracture, Surgery, Arthroscopy, Coracoclavicular fixation, Nonunion


Plan


© 2026  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.