The Neviaser approach for proximal humerus fractures third-generation intramedullary nailing: A cadaver study - 28/03/26

Doi : 10.1016/j.otsr.2025.104577 
Edoardo Giovannetti de Sanctis, Brieuc Monin, Nicolas Bronsard, Jean-François Gonzalez, Marc-Olivier Gauci
 IULS - Institut Universitaire Locomoteur et Sports, Pasteur 2 Hospital, CHU, Nice, France 

Corresponding author.

Abstract

Background

Intramedullary nailing (IMN) for proximal humerus fractures is commonly performed through an anterolateral approach. A percutaneous approach through the Neviaser portal has been shown to be an alternative to avoid cuff tendon insertion violation and be used for a third-generation IMN. The aim of the present cadaver study was to confirm whether the Neviaser approach was reproducible to reach the optimal nail entry point, at the top of the humeral head, passing through the muscular portion of the supraspinatus and to evaluate the risk of biceps and neurovascular bundle damage.

Methods

This was a basic science surgical technique study with sixteen preserved frozen shoulders from 11 donors (8 females, 3 males) used. All surgical procedures were performed using the third-generation AEQUALIS™ IM Nail. Dissection of each specimen was then performed. The nail entry point through the soft-tissue layer was assessed, determining whether the device was inserted through the supraspinatus muscular or tendinous part. A manual caliper with a precision of 0.1 mm was then used to measure the distances of the device to different anatomic structures.

Results

The nails were inserted through the muscular part in all specimens still having a rotator cuff (RC). The mean distances from the nail entry point to the myotendinous junction and RC footprint were 4 mm (range, 2−6 mm) and 39 mm (range, 36−42 mm), respectively. The distances from the lower tuberosity (LT) head screw and most lateral greater tuberosity (GT) head screw to the long head of the biceps (LHB) groove were 9 mm (range, 8−11 mm) and 15 mm (range, 14−17 mm), respectively. The distance of LT head screw to the anterior circumflex pedicle and the lateral cord of the brachial plexus was 15 mm (range 14−17 mm) and 41 mm (range 32−45 mm), respectively. The distance of the highest distal screw and the lowest proximal screw to the axillary nerve was respectively 32 mm (range, 28–40 mm) and 23 mm (range, 21–25 mm). The nail entry point was entirely within the humeral articular surface and at the bone-cartilage junction in 14 and 2 specimens respectively.

Conclusion

This study demonstrated that a third-generation IMN might be inserted via the Neviaser portal. This approach is safe and allows the insertion of the device through the RC muscular part with a reproducible access to the hinge point and with no risk of neurovascular injury.

Level of evidence

IV; Anatomy study; Cadaver Dissection.

Le texte complet de cet article est disponible en PDF.

Keywords : Proximal humeral fractures, Intramedullary nail fixation, Intramedullary nail, Antegrade intramedullary nailing, Antegrade humeral nail


Plan


© 2025  The Author(s). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 112 - N° 2

Article 104577- avril 2026 Retour au numéro
Article précédent Article précédent
  • Influence of posterior and anterolateral approaches on radial nerve palsy incidence and complications following plate fixation of humeral shaft fractures
  • Noé Hugonnier, Cyril Lazerges, Michel Chammas, Pierre-Emmanuel Chammas, Bertrand Coulet, Olivier Bozon
| Article suivant Article suivant
  • Pronator quadratus sutured or not after ORIF by anterior plate: Ultrasound control of its interest in the protection of the Flexor Pollicis Longus
  • François Saade, Camille Bouteille, Raphael Escande, Matthieu Guyard, Philippe Schiele

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.