Use of preload responsiveness tests in pediatric intensive care units: a nationwide prospective clinical practice analysis - 13/04/26

Doi : 10.1016/j.aicoj.2026.100066 
Julien Gotchac a, b, c, , Alice Lecomte c, Yaniss Belaroussi d, Pierre Bourgoin e, Solene Denante f, Roman Klifa c, Elodie Perdreau g, Julian San Geroteo h, Olivier Brissaud c, Arthur Gavotto i, Pascal Amedro a, b

FRAICHE Study Group, Groupe Francophone de Réanimation et d’Urgences Pédiatriques (GFRUP)

a Department of Pediatric and Congenital Cardiology, M3C National Reference Center, Bordeaux University Hospital, Bordeaux, France 
b IHU Liryc, INSERM 1045, University of Bordeaux, Bordeaux, France 
c Pediatric Intensive Care Unit, Children’s Hospital, Bordeaux University Hospital, Bordeaux, France 
d Department of Thoracic Surgery, Haut-Leveque Hospital, Bordeaux University Hospital, Pessac, France 
e Pediatric Intensive Care Unit, Nantes University Hospital, Nantes, France 
f Pediatric Intensive Care Unit, Marseille University Hospital, Marseille, France 
g Pediatric Cardiac Intensive Care Unit, Lyon University Hospital, Lyon, France 
h Pediatric Intensive Care Unit, Robert Debré University Hospital, Paris, France 
i Pediatric Intensive Care Unit, Montpellier University Hospital, Montpellier, France 

Corresponding author at: Department of Pediatric and Congenital Cardiology, M3C National Reference Center, Haut Lévèque Cardiologic Hospital, Bordeaux University Hospital, Avenue Magellan, 33604 Pessac, France. Department of Pediatric and Congenital Cardiology, M3C National Reference Center, Haut Lévèque Cardiologic Hospital Bordeaux University Hospital Avenue Magellan Pessac 33604 France

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Sous presse. Manuscrit accepté. Disponible en ligne depuis le Monday 13 April 2026
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Abstract

Background

To avoid unnecessary volume expansions (VE), several preload-responsiveness tests exist in children but most have strict validity conditions, or are time-consuming. Although underuse or misuse of these tests could lead to inappropriate VE and fluid overload, their actual use in pediatric intensive care units (PICU) has never been evaluated. This study aimed to assess the use of preload-responsiveness tests before VE in PICU, identify clinical factors associated with their use, and document misuse when validity conditions, as defined in the literature, were not met.

Methods

We conducted a prospective nationwide observational study in 34 French PICU. VE prescriptions to children < 15 years were collected during a 6-week period. Exclusion criteria were preterm neonates, mechanical circulatory support, and single-ventricle physiology. For each VE, physicians completed a questionnaire at bedside, focusing on preload-responsiveness test use before VE. Relevant data to interpret tests validity were also collected, including spontaneous breathing and ventilation parameters. The use of preload-responsiveness test, their misuse and the characteristics associated with their use were analyzed. Misuse of a test was defined as its application when validity criteria were not met, regardless of the method used to perform the test which was not recorded.

Results

A total of 471 VE were analyzed, prescribed to children with a median age of 7.9 months, on catecholamine support in 202/471 (42.9%) cases, and intubated in 292/471 (62.0%) cases. The median volume was 10 ml.kg -1 . A preload-responsiveness test was performed before 296/471 (62.8%) VE (95%CI=[58.5%–67.2%]). Inferior vena cava visual analysis was the most common test, performed before 165 VE, followed by the respiratory variability of the peak aortic velocity (ΔVPeak), a dynamic index, measured before 92 VE. Among 294 dynamic indices (i.e., based on respiratory variation in hemodynamic signals) or preload challenges performed, misuse was observed in 188/294 (63.9%) cases. Performing a preload-responsiveness test was independently associated with mechanical ventilation (OR = 3.73, 95%CI=[1.95–7.15], p   <  0.001) and catecholamine support (OR=4.08, 95%CI=[2.00–8.31], p   <  0.001).

Conclusions

In this large national prospective study, preload-responsiveness tests were routinely used before VE in PICU, especially in severe patients. However, the selected tests were often either poorly reliable or misused.

Le texte complet de cet article est disponible en PDF.

List of abbreviations : 95%CI, ΔIVC, ΔVpeak, CAC, CPI, CVC, HR, IVC, LVEDP, MAP, MFC, NIV, PEEP, PICU, PLR, PPV, SAP, SIRS, SVC, TTE, VE, VIS

Keywords : Circulatory failure, Critically ill children, Fluid Responsiveness, Guideline Adherence, Pediatric Intensive Care, Volume Expansion


Plan


© 2026  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.