S'abonner

XEN Gel Stent: efficacité et sécurité à long terme dans la chirurgie du glaucome – étude rétrospective monocentrique - 13/04/26

XEN Gel Stent: long-term safety and efficacy in glaucoma surgery – a single-center retrospective study

Doi : 10.1016/j.jfo.2026.104890 
E. Le Baron 1, , J.-C. Quintyn 1, A. Geneque 1, A. Miguel 1, 2,
1 Centre Hospitalier Universitaire de Caen, France 
2 Hôpital Privé de la Baie, Avranches, France 

Auteur correspondant: Centre Hospitalier Universitaire de Caen, France Centre Hospitalier Universitaire de Caen France
Sous presse. Manuscrit accepté. Disponible en ligne depuis le Monday 13 April 2026

Résumé

Objectif : Évaluer l’efficacité et la sécurité de l’implant XEN®, seul ou combiné à la chirurgie de la cataracte, dans le traitement du glaucome, à long terme.

Matériel et méthode : Dans cette étude rétrospective monocentrique, tous les patients ayant bénéficié d’un implant XEN® entre septembre 2018 et octobre 2023, ont été inclus. Le critère de jugement principal était le taux de succès complet (baisse ≥20 % de la PIO sans médicament hypotonisant ni complication) et qualifié (avec traitement) à 1 mois, 6 mois, 1 an, 2 ans, 3 ans et 5 ans. Les needling n’étaient pas considérés comme des échecs. Les critères secondaires incluaient le nombre d’hypotonisants postopératoires, d’échecs, de complications, de needling , l’acuité visuelle, l’épaisseur de la couche des fibres nerveuses rétiniennes (OCT des FNR) et le champ visuel ( mean deviation ).

Résultats : 101 yeux de 83 patients ont été analysés (41 XEN® seuls, 60 combinés à la chirurgie de la cataracte). Le taux de succès complet passait de 73,3 % à 1 mois à 33,3 % à 5 ans et la PIO moyenne de 17,98mmHg à 13,68mmHg à 5 ans, avec une réduction d’environ 22 % (±4,98). Le nombre de traitements hypotonisants a diminué significativement à tous les temps passant de 3 classes en préopératoire à 1 classe à 5 ans. 38,9 % yeux ont eu au moins un needling . Parmi les 22 (21,8 %) échecs, 10 yeux ont nécessité une reprise par trabéculectomie et 1 cas d’endophtalmie a été noté suite à une exposition du XEN.

Conclusion : Le XEN® offre une réduction efficace et durable de la PIO et des hypotonisants, avec un bon profil d’innocuité, jusqu’à 5 ans chez les patients atteints de glaucome. Cependant, les needling s’avèrent souvent nécessaires, et l'efficacité semble diminuer avec le temps ; de ce fait un suivi postopératoire étroit est requis.

Le texte complet de cet article est disponible en PDF.

Abstract

Objective: The efficacy and safety evaluation of XEN® gel stent implantation, alone and combined with cataract surgery, in glaucoma’s surgical treatment, at short and long term.

Material and method: In this single-center retrospective study, all patients who received a XEN® gel stent between September 2018 and October 2023 were included. The primary outcome was complete success rate (≥20% decrease in IOP without medication or complication) and qualified success rate (with antiglaucoma treatment or minimal complication) at 1 month, 6 months, 1 year, 2 years, 3 years and 5 years. Needlings were not considered as failures. Secondary endpoints included number of postoperative medications, failures, complications, needlings, visual acuity, RNFL OCT and visual field.

Results: 101 eyes of 83 patients were analyzed (41 XEN® single, 60 combined with cataract surgery). Complete success rate went from 73.3% at 1 month to 33.3% at 5 years, and mean IOP from 17.98mmHg to 13.68mmHg at 5 years, with a reduction of around 22%(±4,98). Antiglaucoma medications decreased significantly at all times, from 3 (±0,989 IC95% [0,870;1,149]) classes before surgery to 1 (± 1,328 IC95% [0,997;1,991]) class at 5 years. Needling was needed in 38,9% cases. Among the 22 failures, ten eyes required trabeculectomy to control IOP, and one case of endophthalmitis was noted.

Conclusion: XEN®, alone or in combination, provides effective, long-lasting IOP and medication reduction up to 5 years, with a good safety profile, in glaucoma’s treatment. However, needling is often necessary, and efficacy seems to decrease over time, so, a close post-operative follow-up is required.

Le texte complet de cet article est disponible en PDF.

Mots-clés : Glaucome, Chirurgie filtrante, Chirurgie mini invasive du glaucome, MIGS, MIBS, XEN®

Keywords : Glaucoma, mini invasive glaucoma surgery, MIGS, MIBS, XEN®



© 2026  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.