S'abonner

The impact of near-infrared autofluorescence and indocyanine green fluorescence on surgical management of primary hyperparathyroidism - 13/08/26

Doi : 10.1016/j.jviscsurg.2026.07.021 
Nathanaël Saison a, g, , Frédéric Triponez b, Gianluca Donatini c, Samuel Frey d, Claire Nomine-Criqui e, Eric Mirallié d, Christophe Trésallet f, Paulina Kuczma f
a Department of Surgery, Hospital Center Biel/Bienne, Biel, Switzerland 
b Department of Thoracic and Endocrine Surgery and Faculty of Medicine, University Hospitals of Geneva, Geneva, Switzerland 
c Department of General and Endocrine Surgery, University of Poitiers, CHU Poitiers, Poitiers, France 
d Nantes University, CHU de Nantes, Oncological, Digestive and Endocrine Surgery, Institut des Maladies de l’Appareil Digestif, 44093 Nantes, France 
e University of Lorraine, CHRU-Nancy, Departement of Metabolic and Endocrine Surgery (CVMC), Nancy, France 
f Department of Digestive, Bariatric and Endocrine Surgery, Avicenne University Hospital, Sorbonne Paris Nord University, Assistance Publique–Hôpitaux de Paris, Bobigny, France 
g Clarunis, University Center for Gastrointestinal and Liver Diseases, St Clara Hospital and University Hospital Basel, Basel, Switzerland 

Corresponding author.
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Thursday 13 August 2026

Summary

Surgery constitutes the only curative treatment of primary hyperparathyroidism (PHPT). The difficulty in localizing all hyperfunctioning parathyroid glands can lead to the persistence of the disease and require a surgical reintervention. Complementary intraoperative tools for the localization of hyperfunctioning parathyroid glands remain, however, limited. The objective of this review is to evaluate the role of near-infrared autofluorescence (NIRAF) and fluorescence with indocyanine green (ICG) injection in the surgery of PHPT. NIRAF allows real-time visualization of the parathyroid glands without dye injection and has shown promising results for improving intraoperative detection of the parathyroids. Parathyroid adenomas appear to present specific autofluorescence characteristics. The impact of NIRAF on the cure rate, complication rate, and reduction of operative time in PHPT surgery remains currently uncertain. As the use of NIRAF in PHPT is still in its early stages, only a few studies have analyzed its impact on surgical outcomes. ICG shows promising results for the identification of parathyroid glands and could allow rapid detection of parathyroid adenomas, although this still needs to be validated in larger series. Its most established and relevant use currently remains the evaluation of vascularization and viability of the parathyroid remnant during a subtotal parathyroidectomy. Prospective studies evaluating the use of ICG in PHPT surgery still need to be conducted. The limitations of NIRAF and ICG techniques are the lack of standardized protocols and the additional cost. In conclusion, fluorescence imaging can facilitate the identification of normal and pathological parathyroid glands, increase the surgeon's confidence, and reduce the need for frozen section pathological examination, with a probably greater benefit for less experienced surgeons. Due to the recent emergence of fluorescence in PHPT and therefore an early stage of use, its main current limitations include the absence of standardized protocols and limited evidence regarding its impact on surgical performance and outcomes.

Le texte complet de cet article est disponible en PDF.

Keywords : Fluorescence, Parathyroidectomy, Near-infrared autofluorescence, NIRAF, Indocyanine green injection, ICG, Postoperative outcomes


Plan


© 2026  The Authors. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.