S'abonner

Les systèmes de délivrance automatisée d’insuline face aux situations cliniques particulières : défis et solutions - 29/08/26

Automated insulin delivery systems in special clinical situations: Challenges and solutions

Doi : 10.1016/j.mmm.2026.06.008 
Chloé Amouyal 1, Pierre Yves Benhamou 2, , Aurélie Carlier 3, Lucien Marchand 4, Sarra Smati 5, Orianne Villard 6
au nom de la

Société francophone du diabète (SFD) et de la Société française d’endocrinologie et diabétologie pédiatrique (SFEDP) 7

  Comité de lecture : Jacques Beltrand (AP–HP Centre, hôpital Necker-Enfants-Malades, université de Paris, Paris, France), Pierre Yves Benhamou (Université Grenoble-Alpes, CHU de Grenoble-Alpes, LBFA, endocrinologie, Inserm U1055, Grenoble, France), Elise Bismuth (AP–HP Nord, hôpital Robert-Debré, université de Paris, endocrinologie et diabétologie pédiatrique, Paris, France), Elisabeth Bonnemaison (Clinique Saint-Jean – Saint-Jean-de-Vedas – Montpellier Métropole, Montpellier, France), Lucy Chaillous (CHU de Nantes, institut du Thorax, endocrinologie-diabétologie-nutrition, Nantes, France), Régis Coutant (CHU d’Angers, endocrinologie et diabétologie pédiatrique, Angers, France), Fabienne Dalla-Vale (CHU, endocrinologie et diabétologie pédiatrique, Montpellier, France), Hélène Hanaire (Université de Toulouse, CHU de Rangueil, Toulouse, France), Michaël Joubert (Université de Caen et endocrinologie-diabétologie, CHU de la Côte de Nacre, Caen, France), Sandrine Lablanche (Université Grenoble-Alpes, CHU de Grenoble-Alpes, LBFA, endocrinologie, Inserm U1055, Grenoble, France), Eric Renard (Université de Montpellier, CHU de Montpellier, institut de génomique fonctionnelle, CNRS, endocrinologie-diabétologie, Inserm, Montpellier, France), Yves Reznik (Université de Caen et endocrinologie-diabétologie, CHU de la Côte de Nacre, Caen, France), Pauline Schaepelynck (Hôpital européen, nutrition-endocrinologie-diabétologie, Marseille, France), Nadia Tubiana-Rufi (AP–HP Nord, hôpital Robert-Debré, université de Paris, endocrinologie et diabétologie pédiatrique, Paris, France)

1 AP–HP Pitié-Salpétrière, Sorbonne université, diabétologie, Inserm Nutriomics team, Paris, France 
2 Université Grenoble-Alpes, CHU de Grenoble-Alpes, LBFA, endocrinologie, Inserm U1055, Grenoble, France 
3 AP–HP Bichat, endocrinologie diabétologie, Paris, France 
4 Hôpital Saint-Joseph Saint-Luc, endocrinologie diabétologie, Lyon, France 
5 CHU de Nantes, institut du thorax, endocrinologie diabétologie nutrition, Nantes, France 
6 Université de Montpellier, CHU de Montpellier, institut de génomique fonctionnelle, CNRS, endocrinologie-diabétologie, Inserm, Montpellier, France 

Pierre Yves Benhamou, CHU de Grenoble-Alpes, endocrinologie, CS10217, 38043 Grenoble cedex, France. CHU de Grenoble-Alpes, endocrinologie, CS10217 Grenoble cedex 38043 France

Résumé

La délivrance automatisée d’insuline (DAI) ou insulinothérapie en boucle fermée (BF) s’est imposée en peu d’années comme le standard de soins du diabète de type 1 (DT1), et a également ouvert des perspectives très intéressantes pour le traitement du diabète de type 2. Cependant, si son utilisation en soin courant ambulatoire a fait la preuve de son efficacité et de sa sécurité, il existe des situations cliniques posant question quant à la capacité des algorithmes de régulation glycémique à y faire face. C’est le cas notamment lorsqu’un sujet est confronté à une intervention chirurgicale, une hospitalisation, une maladie intercurrente, une corticothérapie ou une prise en charge en dialyse. La présente prise de position fait le point de la littérature et propose des modalités de gestion de la boucle fermée chez l’adulte et chez l’enfant ou l’adolescent dans ces cinq situations cliniques, en se limitant aux cinq dispositifs actuellement commercialisés en Europe.

Le texte complet de cet article est disponible en PDF.

Summary

Automated insulin delivery (AID), or closed-loop insulin therapy (CL), has become within just a few years the standard of care for type 1 diabetes and has also opened up very promising perspectives for the treatment of type 2 diabetes. However, although its use in routine outpatient care has demonstrated both efficacy and safety, certain clinical situations raise questions about the ability of glycemic control algorithms to cope with them. This is particularly the case when a subject undergoes surgery, hospitalization, intercurrent illness, corticosteroid therapy, or dialysis management. This position statement reviews the available literature and proposes practical guidance for the management of closed-loop therapy in adults and in children or adolescents in these five clinical situations, focusing on the five devices currently marketed in Europe.

Le texte complet de cet article est disponible en PDF.

Mots clés : Délivrance automatisée d’insuline, Insulinothérapie en boucle fermée, Diabète et chirurgie, Diabète et hospitalisation, Corticothérapie, Dialyse

Keywords : Automated insulin delivery, Closed-loop insulin therapy, Diabetes and surgery, Diabetes and hospitalization, Corticosteroid therapy, Dialysis


Plan


© 2026  The Author(s). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 20 - N° 5

P. 409-430 - septembre 2026 Retour au numéro
Article précédent Article précédent
  • Les défis éthiques des systèmes automatisés d’administration d’insuline et des technologies émergentes en diabétologie
  • Jean-Pierre Riveline, Ralph El Khoury, Guy Fagherazzi
| Article suivant Article suivant
  • Gestion des systèmes de délivrance automatisée d’insuline en situation d’activité physique
  • Michael Joubert

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.