Transversal accuracy and stability of segmented Le Fort I osteotomy - 16/09/26

Doi : 10.1016/j.jormas.2026.102982 
Oliver da Costa Senior a, b, , Eman Shaheen a, Ali Reza Pourkarim a, Reinhilde Jacobs a, c, Constantinus Politis a
a OMFS IMPATH research group, Department of Imaging & Pathology, Faculty of Medicine, KU Leuven & Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium 
b Department of Maxillofacial Surgery, ZMACK, AZ MONICA Antwerpen, Antwerp, Belgium; Department of Cranio-Maxillofacial Surgery, Antwerp University Hospital, Edegem, Belgium; Faculty of Medicine & Health Sciences, University of Antwerp, Campus Drie Eiken, Antwerp, Belgium; and All for Research vzw, Antwerp, Belgium 
c Department of Dental Medicine, Karolinska Institutet, Stockholm, Sweden 

Corresponding author.

Abstract

Objectives

To prospectively evaluate the transversal surgical accuracy and one-year stability of segmented Le Fort I osteotomy using a validated three-dimensional (3D) voxel-based assessment protocol.

Methods

In this prospective single-center study, patients undergoing two-piece or three-piece segmented Le Fort I osteotomy for transverse maxillary deficiency were included. Virtual surgical planning was performed using computer-aided design/ manufacturing (CAD/CAM) workflows. Cone-beam computed tomography (CBCT) scans were acquired preoperatively, one week, 6 months and one year postoperatively. The primary outcome was one-year dental transverse relapse, analyzed as a continuous variable. Skeletal transverse width was measured between the greater palatine foramina, and dental width between the maxillary first molars. Segment-specific surgical accuracy and postoperative stability of the lateral maxillary segments were quantified using a validated 3D voxel-based registration protocol across six degrees of freedom. Clinically relevant instability was defined as a transverse relapse of ≥2 mm. Multivariate regression analysis was used to identify predictors of relapse.

Results

Twenty-seven patients (14 two-piece, 13 three-piece) were included. Mean skeletal transverse expansion was 3.75 mm, whereas mean dental expansion was 1.55 mm. At one year, mean skeletal and dental relapse were 0.79 mm and 0.72 mm, respectively. Dental relapse (≥2 mm) occurred in 22.2% of patients, while skeletal relapse (≥2 mm) was observed in 18.2%. Logistic regression demonstrated that greater planned dental expansion significantly increased the risk of dental relapse, with each additional millimeter increasing the odds by 28%. A data-derived Youden threshold of approximately 3.5 mm showed moderate discrimination (specificity 0.81; sensitivity 0.67) but requires external validation. Postoperative roll-related stability changes were associated with dental relapse.

Conclusions

Segmented Le Fort I osteotomy provides predictable skeletal transverse expansion with acceptable one-year stability in this prospective cohort. Dental transverse expansion is more susceptible to relapse than skeletal widening, and greater planned dental expansion increased the risk of clinically relevant dental relapse. Segment-specific 3D assessment suggests that postoperative rotational control, particularly roll stability of the lateral segments, may be relevant for transverse stability.

Le texte complet de cet article est disponible en PDF.

Keywords : Segmented Le Fort I osteotomy, Transverse maxillary expansion, Three-dimensional assessment, Voxel-based registration, Surgical accuracy, Postoperative stability


Plan


© 2026  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 127 - N° 5

Article 102982- octobre 2026 Retour au numéro
Article précédent Article précédent
  • Guideline-based evaluation of five generative artificial intelligence chatbot platforms for clinician-oriented questions on open temporomandibular joint surgery
  • Selin Gaş, Erdinç Sulukan, Büşra Korkmaz
| Article suivant Article suivant
  • First intraoral use of therapeutic oxygen carrier Hemarina-M101 for mandibular osteoradionecrosis: a case report
  • C. Duvaud, J.D. Kün-Darbois, H. Aïssani, A. Gueutier

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.