Comparison of the approaches to combine Renal Replacement Therapy with Extracorporeal Membrane Oxygenation – a Scoping Review - 21/09/26

Doi : 10.1016/j.aicoj.2026.100165 
Eden Kharrouba a, b, ⁎ , Quentin Moyon a, b, c, Matthew E Cove d, Jutta Arens e, Ana Martins Costa e, John F Fraser a, b, f, Jacky Y. Suen a, b
a The University of Queensland, Institute for Molecular Bioscience, Brisbane, Australia 
b Critical Care Research Group, The Prince Charles Hospital, Brisbane, Australia 
c Service de Médecine Intensive Reanimation, Hôpital de la Pitié-Salpêtrière, Sorbonne Université, Paris, France 
d Department of Medicine, National University Hospital, Singapore, Singapore 
e Engineering Organ Support Technologies Group, Department of Biomechanical Engineering, University of Twente, Enschede, the Netherlands 
f School of Medicine, Griffith University, Brisbane, QLD, Australia 

⁎ Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Sous presse. Manuscrit accepté. Disponible en ligne depuis le Monday 21 September 2026

Abstract

Introduction

Extracorporeal membrane oxygenation (ECMO) is increasingly used for cardiac and respiratory failure and is associated with high rates of acute kidney injury (AKI) and fluid overload requiring renal replacement therapy (RRT). ECMO and RRT can be run independently in parallel, or RRT hemofilter or device can be integrated into the ECMO circuit. Several parallel and integrated ECMO-RRT configurations have been described, but the optimal approach remains uncertain.

This scoping review mapped the available literature comparing at least two ECMO-RRT configurations, summarized reported outcomes, and identified knowledge gaps.

Methods

We searched PubMed, Cochrane Library, Web of Science, Embase, and ClinicalTrials.gov without restrictions, with the final search conducted on February 9, 2026. Eligible studies compared at least 2 ECMO-RRT configurations linked to reported outcomes. Data on study characteristics, configurations, outcomes, and anticoagulation were extracted and synthesized.

Results

Of 6,806 records, 20 studies were included: 12 were clinical including 1 randomized controlled trial, 3 in vitro, 1 in silico, and 4 surveys. More than 8 ECMO-RRT connection schemes have been described by clinical studies since 2013. No consistent differences in efficiency or clinical outcomes were observed between the configurations compared. Integrated methods were associated with longer or comparable hemofilter lifespan. Surveys confirmed heterogeneous medical practices, and 2 safety concerns (unstoppable pressure alarms and air embolism) were reported.

Conclusion

Evidence on ECMO-RRT configurations is limited and heterogeneous. Future systematic and rigorous comparison of all the configurations through preclinical and clinical studies is needed to harmonize medical practices and inform the development of guidelines.

Le texte complet de cet article est disponible en PDF.

Keywords : Acute Kidney Injury | Renal Replacement Therapy | Extracorporeal Membrane Oxygenation | Combination | Integration

Abbreviations : AKI, ACT, aPTT, (C)RRT, CVVH, CVVHD, CVVHDF, ECMO, ICU, IHD, LOS, SCUF, SLED, V-A, V-V, V-AV


Plan


© 2026  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.